Optical peroxide biosensor using the electrically controlled-release technique

被引:9
作者
Choi, JW [1 ]
Lim, IH [1 ]
Kim, HH [1 ]
Min, JH [1 ]
Lee, WH [1 ]
机构
[1] Sogang Univ, Dept Chem Engn, Seoul 100611, South Korea
关键词
electrically controlled-release technique; optical enzyme biosensor; peroxidase; peroxide;
D O I
10.1016/S0956-5663(00)00148-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An optical biosensor using an electrically controlled-release system was developed for the measurement of peroxide concentration. The electrically controlled-release system consisted of a current-supplying system and a polymer complex by hydrogen bonding between the carboxylic and oxazoline group. The polymer complex was formed below pH 5.0 and was degraded above pH 5.4. The local pH change near the surface of the polymer complex could be controlled by applying the electric current to release an enzyme reaction reagent, 4-hydroxyphenylacetic acid (HPA), in the polymer complex. The releasing rate of HPA was proportional to the electric current applied to the polymer complex. The model of the controlled-release system was proposed to predict the degradation velocity of the polymer complex, which is equivalent to the releasing rate of HPA. The released HPA and analyte, peroxide, flowed into the reactor with the immobilized enzyme and then reacted with the enzyme. The peroxide concentration was measured based on the fluorescence detection of enzyme reaction product, 6,6'-dihydroxy (1,1'-biphenyl) 3,3'-diacetic acid (DBDA). The proposed biosensor had the linear analytical range of 0.025 similar to 1.0 mM with a response time of 20 min, good repeatability, and reproducibility. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 16 条
[1]   CHARACTERIZATION AND SEMIQUANTITATIVE ESTIMATION OF ORGANO-PHOSPHORUS COMPOUNDS BASED ON INHIBITION OF CHOLINESTERASES [J].
ALFTHAN, K ;
KENTTAMAA, H ;
ZUKALE, T .
ANALYTICA CHIMICA ACTA, 1989, 217 (01) :43-51
[2]  
Baker R.W., 1987, CONTROLLED RELEASE B
[3]   CHEMICAL SENSORS BASED ON CONTROLLED-RELEASE POLYMER SYSTEMS [J].
BARNARD, SM ;
WALT, DR .
SCIENCE, 1991, 251 (4996) :927-929
[4]   CHEMICAL MEASUREMENTS WITH OPTICAL FIBERS FOR PROCESS-CONTROL [J].
BOISDE, G ;
BLANC, F ;
PEREZ, JJ .
TALANTA, 1988, 35 (02) :75-82
[5]  
BUCK RP, 1990, BIOSENSOR TECHNOLOGY, P25
[6]  
Choi JW, 1996, SENSOR MATER, V8, P493
[7]  
Das K. G., 1983, CONTROLLED RELEASE T
[8]  
Fan L., 1989, Controlled release: A quantitative treatment
[9]   FLUORIMETRIC DETERMINATION OF OXIDATIVE ENZYMES - ANALYTICAL APPLICATIONS OF MONOAMINE AND DIAMINE OXIDASE SYSTEMS [J].
GUILBAULT, GG ;
KUAN, SS ;
BRIGNAC, PJ .
ANALYTICA CHIMICA ACTA, 1969, 47 (03) :503-+
[10]  
HEISH P, 1987, CONTROLLED RELEASE S, V1