Tono-Pen determination of intraocular pressure in patients with band keratopathy or glued cornea

被引:23
作者
Azuara-Blanco, A [1 ]
Bhojani, TK [1 ]
Sarhan, AR [1 ]
Pillai, CT [1 ]
Dua, HS [1 ]
机构
[1] Univ Nottingham Hosp, Queens Med Ctr, Dept Ophthalmol, Nottingham NG7 2UH, England
关键词
D O I
10.1136/bjo.82.6.634
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims-To evaluate the intraocular pressure (IOP) measurements in patients with band keratopathy or glued corneas obtained from affected and non-affected areas. Methods-15 patients with band keratopathy or glued corneas were prospectively recruited. When both eyes were affected, only the right eye was analysed. Tone-Pen readings of IOP were obtained sequentially from the affected and non-affected corneal surface. Additionally, Goldmann applanation tonometry was attempted. Results-Determination of IOP with the Tone-Pen was possible in all cases, while Goldmann tonometry was not performed in three patients because of severe corneal irregularities. The average of the Tono-Pen readings obtained from the affected cornea (34.8 (SD 14.0) mm Hg) was consistently and significantly higher (p<0.001) than mean IOP obtained by the Tone-Pen from the non-affected area (14.8 (4.3) mm Hg). The average of Goldmann tonometry readings (14.4 (6.1) mm Hg) did not differ significantly from the Tono-Pen values obtained from the non-affected corneal area (p=0.47) but was significantly lower than the Tone-Pen measurements obtained from the affected area (p<0.001) Conclusion-In patients with band keratopathy or glued corneas determination of IOP by Tone-Pen tonometry varies from affected to non-affected area. The Tono-Pen overestimates the level of IOP when it is applied to areas with band keratopathy or with glue.
引用
收藏
页码:634 / 636
页数:3
相关论文
共 17 条
[1]   ASSESSMENT OF INTRAOCULAR-PRESSURE BY PALPATION [J].
BAUM, J ;
CHATURVEDI, N ;
NETLAND, PA ;
DREYER, EB .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 119 (05) :650-651
[2]  
FRENKEL REP, 1988, ARCH OPHTHALMOL-CHIC, V106, P750
[3]   TONO-PEN TONOMETRY IN NORMAL AND IN POSTKERATOPLASTY EYES [J].
GEYER, O ;
MAYRON, Y ;
LOEWENSTEIN, A ;
NEUDORFER, M ;
ROTHKOFF, L ;
LAZAR, M .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (09) :538-540
[4]  
KAO SF, 1987, OPHTHALMOLOGY, V94, P1541
[5]  
KAUFMAN HE, 1972, INVEST OPHTH VISUAL, V11, P80
[6]   VALIDITY OF MACKAY-MARG ELECTRONIC APPLANATION TONOMETER IN PATIENTS WITH SCARRED IRREGULAR CORNEAS [J].
KAUFMAN, HE ;
WIND, CA ;
WALTMAN, SR .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1970, 69 (06) :1003-&
[7]   COMPARISON OF OCULAB TONO-PEN READINGS OBTAINED FROM VARIOUS CORNEAL AND SCLERAL LOCATIONS [J].
KHAN, JA ;
DAVIS, M ;
GRAHAM, CE ;
TRANK, J ;
WHITACRE, MM .
ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (10) :1444-1446
[8]  
LANGHAM ME, 1968, ARCH OPHTHALMOL-CHIC, V79, P388
[9]   AUTOMATIC TONOMETER WITH EXACT THEORY - VARIOUS BIOLOGICAL APPLICATIONS [J].
MACKAY, RS ;
MARG, E ;
OECHSLI, R .
SCIENCE, 1960, 131 (3414) :1668-1669
[10]  
MCMILLAN F, 1975, ARCH OPHTHALMOL-CHIC, V93, P420