Compact movable microwire array for long-term chronic unit recording in cerebral cortex of primates

被引:126
作者
Jackson, Andrew
Fetz, Eberhard E.
机构
[1] Univ Washington, Dept Physiol & Biophys, Newcastle Upon Tyne, Tyne & Wear, England
[2] Univ Washington, Washington Natl Primate Res Ctr, Newcastle Upon Tyne, Tyne & Wear, England
关键词
D O I
10.1152/jn.00569.2007
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We describe a small, chronically implantable microwire array for obtaining long-term unit recordings from the cortex of unrestrained nonhuman primates. After implantation, the depth of microwires can be individually adjusted to maintain large-amplitude action potential recordings from single neurons over many months. We present data recorded from the primary motor cortex of two monkeys by autonomous on-board electronic circuitry. Waveforms of individual neurons remained stable for recording periods of several weeks during unrestrained behavior. Signal-to-noise ratios, waveform stability, and rates of cell loss indicate that this method may be particularly suited to experiments investigating the neural correlates of processes extending over multiple days, such as learning and plasticity.
引用
收藏
页码:3109 / 3118
页数:10
相关论文
共 29 条
[1]   Multiple single unit recording in the cortex of monkeys using independently moveable microelectrodes [J].
Baker, SN ;
Philbin, N ;
Spinks, R ;
Pinches, EM ;
Wolpert, DM ;
MacManus, DG ;
Pauluis, Q ;
Lemon, RN .
JOURNAL OF NEUROSCIENCE METHODS, 1999, 94 (01) :5-17
[2]   Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays [J].
Biran, R ;
Martin, DC ;
Tresco, PA .
EXPERIMENTAL NEUROLOGY, 2005, 195 (01) :115-126
[3]   Learning to control a brain-machine interface for reaching and grasping by primates [J].
Carmena, JM ;
Lebedev, MA ;
Crist, RE ;
O'Doherty, JE ;
Santucci, DM ;
Dimitrov, DF ;
Patil, PG ;
Henriquez, CS ;
Nicolelis, MAL .
PLOS BIOLOGY, 2003, 1 (02) :193-208
[4]   Semi-chronic motorized microdrive and control algorithm for autonomously isolating and maintaining optimal extracellular action potentials [J].
Cham, JG ;
Branchaud, EA ;
Nenadic, Z ;
Greger, B ;
Andersen, RA ;
Burdick, JW .
JOURNAL OF NEUROPHYSIOLOGY, 2005, 93 (01) :570-579
[5]   A NEW METHOD FOR THE INSERTION OF MULTIPLE MICROPROBES INTO NEURAL AND MUSCULAR TISSUE, INCLUDING FIBER ELECTRODES, FINE WIRES, NEEDLES AND MICROSENSORS [J].
ECKHORN, R ;
THOMAS, U .
JOURNAL OF NEUROSCIENCE METHODS, 1993, 49 (03) :175-179
[6]  
GRAY CM, 2006, SOC NEUROSCI ABSTR
[7]   Long-term gliosis around chronically implanted platinum electrodes in the Rhesus macaque motor cortex [J].
Griffith, Ronald W. ;
Humphrey, Donald R. .
NEUROSCIENCE LETTERS, 2006, 406 (1-2) :81-86
[8]   Nanoscale laminin coating modulates cortical scarring response around implanted silicon microelectrode arrays [J].
He, Wei ;
McConnell, George C. ;
Bellamkonda, Ravi V. .
JOURNAL OF NEURAL ENGINEERING, 2006, 3 (04) :316-326
[9]   Correlations between the same motor cortex cells and arm muscles during a trained task, free behavior, and natural sleep in the macaque monkey [J].
Jackson, Andrew ;
Mavoori, Jaideep ;
Fetz, Eberhard E. .
JOURNAL OF NEUROPHYSIOLOGY, 2007, 97 (01) :360-374
[10]   The Neurochip BCI: Towards a neural prosthesis for upper limb function [J].
Jackson, Andrew ;
Moritz, Chet T. ;
Mavoori, Jaideep ;
Lucas, Timothy H. ;
Fetz, Eberhard E. .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2006, 14 (02) :187-190