Flat-panel CT as a new perinterventional imaging modality in aortic stentgraft procedures - Work in progress

被引:6
作者
Rabitsch, E. [1 ]
Celedin, S. [1 ]
Kau, T. [1 ]
Illiasch, H. [1 ]
Hausegger, K. [1 ]
机构
[1] Inst diagnost & Intervent Radiol, LKH Klagenfurt, D-9020 Klagenfurt, Austria
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2008年 / 180卷 / 02期
关键词
aneurysm; vascular; grafts; interventional procedures; CT angiography;
D O I
10.1055/s-2007-963667
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the value of flat-panel CT (FP-CT) as a new perinterventional imaging modality in aortic stentgraft procedures. Materials and Methods: FP-CT was performed in 21 patients (19 males, mean age 77, range 54 to 90) from June 2005 to February 2007 immediately after endovascular treatment of thoracic and abdominal aortic aneurysms on the angiographic table. Nine thoracic aortic aneurysms were treated with Zenith (TM)-endoprosthesis. Nine of twelve abdominal aortic aneurysms were treated with Zenith (TM)-Endoprosthesis and three with an Excluder (TM)-Endoprosthesis. Images were acquired with a rotating C-arm and the following parameters: during an acquisition time of 20 seconds and at a rotation of 217 degrees, 538 projections were acquired. Contrast agent was administered in 14 patients. Images were displayed in MIP, MPR and VRT mode. Results: In all patients the stentgraft was shown exactly and the alignment of the prosthesis along the landing zones was well displayed. The aneurismal sack was well shown in all patients. 1 x an endoleak II was detected, 1 x an angiographically verified endoleak I was not detected. In one patient distal extension was considered due to suspected short stentgraft at the distal neck. Flat-panel CT showed sufficient neck coverage and no extension was inserted. Due to artifacts of the prosthesis, the platinum markers and the guide wire as well as due to pulsation of the aorta the, resolution of detail decreased and reduced the visualization of the alignment. Conclusion: FP-CT is a promising tool and may provide additional information, but further studies are necessary to define the value of flat-pa, nel CT in thoracic and abdominal aortic stentgraft procedures.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 8 条
[1]   Elective treatment of abdominal aortic aneurysm with endovascular or open repair: The first decade [J].
Chahwan, Santiago ;
Comerota, Anthony J. ;
Pigott, John P. ;
Scheuermann, Barry W. ;
Burrow, Julia ;
Wojnarowski, Dennis .
JOURNAL OF VASCULAR SURGERY, 2007, 45 (02) :258-262
[2]   Initial observations of endovascular aneurysm repair using Dyna-CT [J].
Eide, Kari Ravn ;
Odegard, Asbjorn ;
Myhre, Hans Olav ;
Haraldseth, Olav .
JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 (01) :50-53
[3]   Comparison of endovascular aneurysm repair with open repair in patients with abdominal aortic aneurysm (EVAR trial 1), 30-day operative mortality results: randomised controlled trial [J].
Greenhalgh, RM ;
Brown, LC ;
Kwong, GPS ;
Powell, JT ;
Thompson, SG .
LANCET, 2004, 364 (9437) :843-848
[4]  
Kalender WA, 2003, RADIOLOGE, V43, P379, DOI 10.1007/s00117-003-0897-4
[5]   Classification and treatment of endoleaks after endovascular treatment of abdominal aortic aneurysms [J].
Pitton, MB ;
Schmiedt, W ;
Neufang, A ;
Düber, C ;
Thelen, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (01) :24-34
[6]   Design and performance characteristics of a digital flat-panel computed tomography system [J].
Ross, William ;
Cody, Dianna D. ;
Hazle, John D. .
MEDICAL PHYSICS, 2006, 33 (06) :1888-1901
[7]   Flat detectors and their clinical applications [J].
Spahn, M .
EUROPEAN RADIOLOGY, 2005, 15 (09) :1934-1947
[8]   Reducing metal artifacts in cone-beam CT images by preprocessing projection data [J].
Zhang, Yongbin ;
Zhang, Lifei ;
Zhu, Ronald ;
Lee, Andrew K. ;
Chambers, Mark ;
Dong, Lei .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (03) :924-932