Esophageal Doppler: Noninvasive cardiac output monitor

被引:39
作者
Cholley, BP [1 ]
Singer, M [1 ]
机构
[1] Middlesex Hosp, Bloomsbury Inst Intens Care Med, London, England
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2003年 / 20卷 / 08期
关键词
ultrasound imaging; cardiac function; transesophageal echocardiography;
D O I
10.1111/j.0742-2822.2003.03033.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this article we describe the esophageal Doppler, a noninvasive, instantaneous cardiac output monitor. Its reliability has been demonstrated to be comparable to that of other current techniques used in the clinical arena to measure cardiac output. It helps guiding intravascular fluid resuscitation by quantifying the increase in flow in response to fluid challenges and by indicating the plateau of the patient's cardiac function curve. When the plateau has been reached, further fluid loading may result in congestion without improvement in systemic flow. Thus, measuring cardiac output is the only way to determine the upper limit for fluid intake. In addition, a strategy based on cardiac output optimization has proven beneficial in high-risk surgical patients.
引用
收藏
页码:763 / 769
页数:7
相关论文
共 45 条
  • [21] Kaul S, 1994, J Am Soc Echocardiogr, V7, P598
  • [22] NONINVASIVE AORTIC BLOOD-FLOW MEASUREMENT USING AN INTRAESOPHAGEAL PROBE
    LAVANDIER, B
    CATHIGNOL, D
    MUCHADA, R
    XUAN, BB
    MOTIN, J
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (03) : 451 - 460
  • [23] Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients
    Lefrant, JY
    Bruelle, P
    Aya, AGM
    Saissi, G
    Dauzat, M
    de La Coussaye, JE
    Eledjam, JJ
    [J]. INTENSIVE CARE MEDICINE, 1998, 24 (04) : 347 - 352
  • [24] MARK JB, 1986, ANESTH ANALG, V65, P1013
  • [25] MYTHEN MG, 1995, ARCH SURG-CHICAGO, V130, P423
  • [26] PERRINO AC, 1991, ANESTH ANALG, V73, P705
  • [27] INTRAOPERATIVE TRANSESOPHAGEAL ECHOCARDIOGRAPHY FOR THE DETECTION OF CARDIAC PRELOAD CHANGES INDUCED BY TRANSFUSION AND PHLEBOTOMY IN PEDIATRIC-PATIENTS
    REICH, DL
    KONSTADT, SN
    NEJAT, M
    ABRAMS, HP
    BUCEK, J
    [J]. ANESTHESIOLOGY, 1993, 79 (01) : 10 - 15
  • [28] Early goal-directed therapy in the treatment of severe sepsis and septic shock.
    Rivers, E
    Nguyen, B
    Havstad, S
    Ressler, J
    Muzzin, A
    Knoblich, B
    Peterson, E
    Tomlanovich, M
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (19) : 1368 - 1377
  • [29] SCHMID ER, 1993, ANESTH ANALG, V77, P971
  • [30] THE ROLE OF PHYSIOLOGIC MONITORING IN PATIENTS WITH FRACTURES OF THE HIP
    SCHULTZ, RJ
    WHITFIELD, GF
    LAMURA, JJ
    RACITI, A
    KRISHNAMURTHY, S
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1985, 25 (04): : 309 - 316