Optimisation of T2 and M0 measurements of bi-exponential systems

被引:39
作者
Anastasiou, A [1 ]
Hall, LD [1 ]
机构
[1] Univ Cambridge, Sch Clin Med, Herchel Smith Lab Med Chem, Cambridge CB2 2PZ, England
关键词
bi-exponential; Cramer-Rao; sclerosis; bone; MRI;
D O I
10.1016/j.mri.2003.05.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cramer-Rao theory and computer simulations were used to show that the errors involved in calculating the magnetization and relaxation parameters of a two-component system decrease with: (1) increasing SNR, (2) increasing number of echoes used in the fitting procedure, and (3) increasing ratio of the relaxation times of the two components, T-22/T-21. Images of bi-compartmental phantoms of known T-2 values were acquired using an optimized imaging sequence, and an optimized fitting algorithm was used to calculate the T-2 values of the two components by fitting the resulting images to a bi-exponential decay model. Accuracy better than 6% was achieved in the calculations of the T-2 values of the two components, and region fitting provided better accuracy than pixel-by-pixel fitting. The procedures were used to calculate the T-2 and M-0 values of equine carpal bones with known degree of radiographic bone sclerosis. Although the T-2 and M-0 values of both water and fat components all decreased with the degree of radiographic bone sclerosis, the transverse relaxation of the water component. T-2w, showed a greater decrease with advanced stages of bone sclerosis. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:67 / 80
页数:14
相关论文
共 48 条
[41]   The accuracy of the dorsoproximal-dorsodistal projection in assessing third carpal bone sclerosis in standardbred trotters [J].
Uhlhorn, H ;
Ekman, S ;
Haglund, A ;
Carlsten, J .
VETERINARY RADIOLOGY & ULTRASOUND, 1998, 39 (05) :412-417
[42]   BONE-MARROW IMAGING [J].
VOGLER, JB ;
MURPHY, WA .
RADIOLOGY, 1988, 168 (03) :679-693
[43]   Measurement of R2′ in the presence of multiple spectral components using reference spectrum deconvolution [J].
Wehrli, FW ;
Ma, J ;
Hopkins, JA ;
Song, HK .
JOURNAL OF MAGNETIC RESONANCE, 1998, 131 (01) :61-68
[44]   OSTEOPOROSIS - CLINICAL-ASSESSMENT WITH QUANTITATIVE MR-IMAGING IN DIAGNOSIS [J].
WEHRLI, FW ;
FORD, JC ;
HADDAD, JG .
RADIOLOGY, 1995, 196 (03) :631-641
[45]   TRABECULAR STRUCTURE - PRELIMINARY APPLICATION OF MR-INTERFEROMETRY [J].
WEHRLI, FW ;
FORD, JC ;
ATTIE, M ;
KRESSEL, HY ;
KAPLAN, FS .
RADIOLOGY, 1991, 179 (03) :615-621
[46]   CHOICE OF OPTIMAL PARAMETERS FOR MEASUREMENT OF SPIN-LATTICE RELAXATION-TIMES .1. MATHEMATICAL FORMULATION [J].
WEISS, GH ;
GUPTA, RK ;
FERRETTI, JA ;
BECKER, ED .
JOURNAL OF MAGNETIC RESONANCE, 1980, 37 (03) :369-379
[47]  
YOUNG DR, 1991, AM J VET RES, V52, P402
[48]   A PHASE-CYCLING TECHNIQUE FOR CANCELING SPURIOUS ECHOES IN NMR IMAGING [J].
ZUR, Y ;
STOKAR, S .
JOURNAL OF MAGNETIC RESONANCE, 1987, 71 (02) :212-228