Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure

被引:290
作者
Wilke, Hans-Joachim [1 ]
Drumm, J. [2 ]
Haeussler, K. [1 ]
Mack, C. [1 ]
Steudel, W. -I. [2 ]
Kettler, A. [1 ]
机构
[1] Univ Ulm, Inst Orthopaed Res & Biomech Director L Claes, D-89081 Ulm, Germany
[2] Saarland Univ Hosp, Dept Neurosurg, Homburg, Germany
关键词
lumbar spine; interspinous implant; biomechanics; flexibility; intradiscal pressure;
D O I
10.1007/s00586-008-0657-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Interspinous implants are used to treat lumbar spinal stenosis or facet joint arthritis. The aims of implanting interspinous devices are to unload the facet joints, restore foraminal height and provide stability especially in extension but still allow motion. The aim of this in vitro study was to compare four different interspinous implants-Colfex, Wallis, Diam and X-Stop-in terms of their three-dimensional flexibility and the intradiscal pressure. Twenty-four human lumbar spine specimens were divided into four equal groups and tested with pure moments in flexion/extension, lateral bending and axial rotation: (1) intact, (2) defect, (3) after implantation. Range of motion and the intradiscal pressure were determined.In each implant-group the defect caused an increase in range of motion by about 8% in lateral bending to 18% in axial rotation. Implantation had similar effects with all four implants. In extension, Coflex, Wallis, Diam, and X-Stop all overcompensated the instability caused by the defect and allowed about 50% of the range of motion of the intact state. In contrast, in flexion, lateral bending and axial rotation the values of the range of motion stayed about the values of the defect state. Similarly the intradiscal pressure after implantation was similar to that of the intact specimens in flexion, lateral bending and axial rotation but much smaller during extension. All tested interspinous implants had a similar effect on the flexibility: they strongly stabilized and reduced the intradiscal pressure in extension, but had almost no effect in flexion, lateral bending and axial rotation.
引用
收藏
页码:1049 / 1056
页数:8
相关论文
共 18 条
[1]
Lumbar spinal stenosis:: Conservative or surgical management?: A prospective 10-year study [J].
Amundsen, T ;
Weber, H ;
Nordal, HJ ;
Magnaes, B ;
Abdelnoor, M ;
Lilleås, F .
SPINE, 2000, 25 (11) :1424-1435
[2]
Dynamic interspinous process technology [J].
Christie, SD ;
Song, JK ;
Fessler, RG .
SPINE, 2005, 30 (16) :S73-S78
[3]
The relationship between disc degeneration, facet joint osteoarthritis, and stability of the degenerative lumbar spine [J].
Fujiwara, A ;
Tamai, K ;
An, HS ;
Kurihashi, A ;
Lim, TH ;
Yoshida, H ;
Saotome, K .
JOURNAL OF SPINAL DISORDERS, 2000, 13 (05) :444-450
[4]
Intradiscal pressure measurements in normal discs, compressed discs and compressed discs treated with axial posterior disc distraction: an experimental study on the rabbit lumbar spine model [J].
Guehring, Thorsten ;
Unglaub, Frank ;
Lorenz, Helga ;
Omlor, Georg ;
Wilke, Hans-Joachim ;
Kroeber, Markus W. .
EUROPEAN SPINE JOURNAL, 2006, 15 (05) :597-604
[5]
A microstructure based fiberoptic pressure sensor for measurements in lumbar intervertebral discs. [J].
Höjer, S ;
Krantz, M ;
Ekström, L ;
Kaigle, A ;
Holm, S .
BIOMEDICAL SENSORS, FIBERS, AND OPTICAL DELIVERY SYSTEMS, PROCEEDINGS, 1999, 3570 :115-122
[6]
Are the spines of calf, pig and sheep suitable models for pre-clinical implant tests? [J].
Kettler, A. ;
Liakos, L. ;
Haegele, B. ;
Wilke, H. -J. .
EUROPEAN SPINE JOURNAL, 2007, 16 (12) :2186-2192
[7]
The effects of an interspinous implant on the kinematics of the instrumented and adjacent levels in the lumbar spine [J].
Lindsey, DP ;
Swanson, KE ;
Fuchs, P ;
Hsu, KY ;
Zucherman, JF ;
Yerby, SA .
SPINE, 2003, 28 (19) :2192-2197
[8]
Preliminary design and experimental studies of a novel soft implant for correcting sagittal plane instability in the lumbar spine [J].
Minns, RJ ;
Walsh, WK .
SPINE, 1997, 22 (16) :1819-1825
[9]
Dynamic stabilization of the lumbar spine and its effects on adjacent segments - An in vitro experiment [J].
Schmoelz, W ;
Huber, JF ;
Nydegger, T ;
Claes, L ;
Wilke, HJ .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2003, 16 (04) :418-423
[10]
Nonoperative treatment for lumbar spinal stenosis - Clinical and outcome results and a 3-year survivorship analysis [J].
Simotas, AC ;
Dorey, FJ ;
Hansraj, KK ;
Cammisa, F .
SPINE, 2000, 25 (02) :197-203