Subtle blood-brain barrier leakage rate and spatial extent: Considerations for dynamic contrast-enhanced MRI

被引:74
作者
van de Haar, Harm J. [1 ,2 ]
Jansen, Jacobus F. A.
Jeukens, Cecile R. L. P. N.
Burgmans, Saartje
van Buchem, Mark A.
Muller, Majon
Hofman, Paul A. M. [3 ]
Verhey, Frans R. J. [3 ]
van Osch, Matthias J. P.
Backes, Walter H. [3 ]
机构
[1] Maastricht Univ Med Ctr, Dept Radiol & Nucl Med, NL-6202 Maastricht, AZ, Netherlands
[2] Maastricht Univ Med Ctr, Dept Neuropsychol & Psychiat Alzheimer Ctr Limbur, NL-6200 Maastricht, MD, Netherlands
[3] Maastricht Univ, Sch Mental Hlth & Neurosci, NL-6200 Maastricht, MD, Netherlands
关键词
Alzheimer's disease; blood-brain barrier; brain MRI; dynamic contrast-enhanced MRI; leakage; pharmacokinetic modeling; DCE-MRI; TEMPORAL RESOLUTION; IN-VIVO; PERMEABILITY; PARAMETERS; QUANTIFICATION; ACQUISITION; BREAKDOWN; DISEASE; VOLUME;
D O I
10.1002/mp.12328
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Dynamic contrast-enhanced (DCE) MRI can be used to measure blood-brain barrier (BBB) leakage. In neurodegenerative disorders such as small vessel disease and dementia, the leakage can be very subtle and the corresponding signal can be rather noisy. For these reasons, an optimized DCE-MRI measurement and study design is required. To this end, a new measure indicative of the spatial extent of leakage is introduced and the effects of scan time and sample size are explored. Methods: Dual-time resolution DCE-MRI was performed in 16 patients with early Alzheimer's disease (AD) and 17 healthy controls. The leakage rate (K-i) and volume fraction of detectable leaking tissue (v(L)) to quantify the spatial extent of BBB leakage were calculated in cortical gray matter and white matter using noise-corrected histogram analysis of leakage maps. Computer simulations utilizing realistic K-i histograms, mimicking the strong effect of noise and variation in K-i values, were performed to understand the influence of scan time on the estimated leakage. Results: The mean K-i was very low (order of 10(-4) min(-1)) and highly influenced by noise, causing the K-i to be increasingly overestimated at shorter scan times. In the white matter, the K-i was not different between patients with early AD and controls, but was higher in the cortex for patients, reaching significance after 14.5 min of scan time. To detect group differences, v(L) proved more suitable, showing significantly higher values for patients compared with controls in the cortex after 8 minutes of scan time, and in white matter after 15.5 min. Conclusions: Several ways to improve the sensitivity of a DCE-MRI experiment to subtle BBB leakage were presented. We have provided v(L) as an attractive and potentially more time-efficient alternative to detect group differences in subtle and widespread blood-brain barrier leakage compared with leakage rate K-i. Recommendations on group size and scan time are made based on statistical power calculations to aid future research. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:4112 / 4125
页数:14
相关论文
共 37 条
[11]   A comparison of Ktrans measurements obtained with conventional and first pass pharmacokinetic models in human gliomas [J].
Haroon, HA ;
Buckley, DL ;
Patankar, TA ;
Dow, GR ;
Rutherford, SA ;
Balériaux, D ;
Jackson, A .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (05) :527-536
[12]   Tracer kinetic modelling for DCE-MRI quantification of subtle blood-brain barrier permeability [J].
Heye, Anna K. ;
Thrippleton, Michael J. ;
Armitage, Paul A. ;
Hernandez, Maria del C. Valdes ;
Makin, Stephen D. ;
Glatz, Andreas ;
Sakka, Eleni ;
Wardlaw, Joanna M. .
NEUROIMAGE, 2016, 125 :446-455
[13]   Assessment of blood-brain barrier disruption using dynamic contrast-enhanced MRI. A systematic review [J].
Heye, Anna K. ;
Culling, Ross D. ;
Valdes Hernandez, Maria del C. ;
Thrippleton, Michael J. ;
Wardlaw, Joanna M. .
NEUROIMAGE-CLINICAL, 2014, 6 :262-274
[14]   Dual-Temporal Resolution Dynamic Contrast-Enhanced MRI Protocol for Blood-Brain Barrier Permeability Measurement in Enhancing Multiple Sclerosis Lesions [J].
Jelescu, I. O. ;
Leppert, I. R. ;
Narayanan, S. ;
Araujo, D. ;
Arnold, D. L. ;
Pike, G. B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (06) :1291-1300
[15]   Temporal Resolution and SNR Requirements for Accurate DCE-MRI Data Analysis Using the AATH Model [J].
Kershaw, Lucy E. ;
Cheng, Hai-Ling Margaret .
MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (06) :1772-1780
[16]   Models and methods for analyzing DCE-MRI: A review [J].
Khalifa, Fahmi ;
Soliman, Ahmed ;
El-Baz, Ayman ;
Abou El-Ghar, Mohamed ;
El-Diasty, Tarek ;
Gimel'farb, Georgy ;
Ouseph, Rosemary ;
Dwyer, Amy C. .
MEDICAL PHYSICS, 2014, 41 (12)
[17]   Measurement of Brain Perfusion, Blood Volume, and Blood-Brain Barrier Permeability, Using Dynamic Contrast-Enhanced T1-Weighted MRI at 3 Tesla [J].
Larsson, Henrik B. W. ;
Courivaud, Frederic ;
Rostrup, Egill ;
Hansen, Adam E. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (05) :1270-1281
[18]   Reproducibility of the gadolinium concentration measurements and of the fitting parameters of the vascular input function in the superior sagittal sinus in a patient population [J].
Lavini, Cristina ;
Verhoeff, Joost J. C. .
MAGNETIC RESONANCE IMAGING, 2010, 28 (10) :1420-1430
[19]   Resting-State fMRI: A Review of Methods and Clinical Applications [J].
Lee, M. H. ;
Smyser, C. D. ;
Shimony, J. S. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (10) :1866-1872
[20]  
Li K L, 2000, J Magn Reson Imaging, V12, P347, DOI 10.1002/1522-2586(200008)12:2<347::AID-JMRI19>3.0.CO