Characterization of Differences between Blood Sample Matrices in Untargeted Metabolomics

被引:90
作者
Denery, Judith R. [1 ]
Nunes, Ashlee A. K.
Dickerson, Tobin J.
机构
[1] Scripps Res Inst, Dept Chem, La Jolla, CA 92037 USA
关键词
TANDEM MASS-SPECTROMETRY; COLLECTION PROCEDURES; HEPARINIZED PLASMA; SERUM; CHROMATOGRAPHY; DISEASE; CANCER; SPOTS; LYSOPHOSPHATIDYLINOSITOL; LYSOPHOSPHOLIPIDS;
D O I
10.1021/ac102806p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Large-scale proteomic and metabolomic technologies are increasingly gaining attention for their use in the diagnosis of human disease. In order to ensure the statistical power of relevant markers, such analyses must incorporate a large number of representative samples. While in a best-case scenario these samples are collected through a study design that is specifically tailored for the desired analysis, often studies must rely upon the analysis of large numbers of previously banked samples that may or may not have complete and accurate documentation of their associated collection and storage methods. In this study, several human blood matrices were analyzed and compared or the quality of metabolomic output The sample types that were tested include plasma prepared with a variety of anticoagulants and serum collected by venipuncture and capillary blood collection protocols. Analysis with liquid chromatography mass spectrometry (LC-MS) revealed only subtle differences between the various plasma preparation methods. Differences between the serum and plasma samples appear to be largely peptide/protein-based and are consistent with the biological distinction of the two matrices. Interestingly, the small molecule lysophosphatidylinositol was found to be in higher abundance in plasma, as a possible consequence of the effect of the intrinsic dotting cascade on adjacent metabolic pathways. Comparison of the small-molecule profiles of the capillary- and venipuncture-collected samples revealed 23 statistically significant compound differences between these sample types. Most of these features can be attributed to sufactants and detergents used to pretreat the skin in order to maintain the sterility of sample collection. However, several have identical mass and molecular formulas as endogenous human metabolites and could be erroneously attributed to actual metabolic perturbations. Understanding the extent of these matrix effects is important for control of systematic bias and ensuring the quality of metabolomic analysis.
引用
收藏
页码:1040 / 1047
页数:8
相关论文
共 49 条
[21]  
LADENSON JH, 1974, AM J CLIN PATHOL, V62, P545
[22]  
LUM G, 1974, AM J CLIN PATHOL, V61, P108
[23]   Serum or plasma samples? The "Cinderella" role of blood collection procedures - Preanalytical methodological issues influence the release and activity of circulating matrix metalloproteinases and their tissue inhibitors, hampering diagnostic trueness and leading to misinterpretation [J].
Mannello, Ferdinando .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2008, 28 (04) :611-614
[24]   Genomic and metabolomic advances in the identification of disease and adverse event biomarkers [J].
Mendrick, Donna L. ;
Schnackenberg, Laura .
BIOMARKERS IN MEDICINE, 2009, 3 (05) :605-615
[25]   Liquid chromatography mass spectrometry for quantifying plasma lysophospholipids: Potential biomarkers for cancer diagnosis [J].
Murph, Mandi ;
Tanaka, Tamotsu ;
Pang, Jihai ;
Felix, Edward ;
Liu, Shuying ;
Trost, Rosanne ;
Godwin, Andrew K. ;
Newman, Robert ;
Mills, Gordon .
LIPIDOMICS AND BIOACTIVE LIPIDS: SPECIALIZED ANALYTICAL METHODS AND LIPIDS IN DISEASE, 2007, 433 :1-+
[26]  
Pacific Northwest National Laboratory, Venn Diagram Plotter
[27]   A multivariate screening strategy for investigating metabolic effects of strenuous physical exercise in human serum [J].
Pohjanen, Elin ;
Thysell, Elin ;
Jonsson, Par ;
Eklund, Caroline ;
Silfver, Anders ;
Carlsson, Inga-Britt ;
Lundgren, Krister ;
Moritz, Thomas ;
Svensson, Michael B. ;
Antti, Henrik .
JOURNAL OF PROTEOME RESEARCH, 2007, 6 (06) :2113-2120
[28]   Optimization of protein precipitation based upon effectiveness of protein removal and ionization effect in liquid chromatography-tandem mass spectrometry [J].
Polson, C ;
Sarkar, P ;
Incledon, B ;
Raguvaran, V ;
Grant, R .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (02) :263-275
[29]   HUPO Plasma Proteome Project specimen collection and handling: Towards the standardization of parameters for plasma proteome samples [J].
Rai, AJ ;
Gelfand, CA ;
Haywood, BC ;
Warunek, DJ ;
Yi, JZ ;
Schuchard, MD ;
Mehigh, RJ ;
Cockrill, SL ;
Scott, GBI ;
Tammen, H ;
Schulz-Knappe, P ;
Speicher, DW ;
Vitzthum, F ;
Haab, BB ;
Siest, G ;
Chan, DW .
PROTEOMICS, 2005, 5 (13) :3262-3277
[30]   How to improve reliability and efficiency of research about molecular markers: roles of phases, guidelines, and study design [J].
Ransohoff, David F. .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2007, 60 (12) :1205-1219