Does High Hip Center Decrease Range of Motion in Total Hip Arthroplasty? A Computer Simulation Study

被引:51
作者
Komiyama, Keisuke [1 ]
Nakashima, Yasuharu [1 ]
Hirata, Masanobu [1 ]
Hara, Daisuke [1 ]
Kohno, Yusuke [1 ]
Iwamoto, Yukihide [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthoped Surg, Fukuoka, Japan
基金
日本学术振兴会;
关键词
high hip center; hip dysplasia; range of motion; total hip arthroplasty; computer simulation; TERM-FOLLOW-UP; DEVELOPMENTAL DYSPLASIA; ACETABULAR COMPONENT; DISLOCATION; REPLACEMENT; POLYETHYLENE; MINIMUM; 10-YEAR; GRAFTS; JOINT;
D O I
10.1016/j.arth.2016.03.014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: High placement of a cementless acetabular cup is often required to have sufficient bone coverage in hip dysplasia. We examined whether a high hip center decreases the postoperative range of motion (ROM) in total hip arthroplasty. Methods: Using a computer software, ROM and bone coverage were examined in 32 patients with unilateral osteoarthritis of the hip with Crowe type II or III hip dysplasia. The cup was placed at the anatomic hip center and moved vertically in 5-mm increments. Vertical center of rotation (V-COR) was defined as the distance from the head center to the interteardrop line. The required ROM was defined as flexion >= 110 degrees, internal rotation (IR) at 90 degrees flexion >= 30 degrees, extension >= 30 degrees, and external rotation >= 30 degrees. We determined the V-COR to satisfy the required ROM and cup center-edge angle (Cup-CE) >= 0 degrees. Results: Only 40.6% of the patients satisfied Cup-CE >= 0 degrees at the anatomic hip center. Bone coverage increased with the peak at 30, 35 mm of V-COR (90.6% satisfied Cup-CE >= 0 degrees) and decreased at >= 40 mm. Higher V-COR resulted in lower range of flexion and IR, but increased the range of extension and external rotation. The cutoff value from the receiver-operating characteristic curve for both flexion and IR was a V-COR of 35 mm. Conclusion: The higher hip center gained more bone coverage but decreased the range of hip flexion and IR. Acceptable V-COR in hip dysplasia was around 35 mm, about 20 mm above the true hip center, in terms of ROM. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:2342 / 2347
页数:6
相关论文
共 34 条
[1]
The effect of femoral component head size on posterior dislocation of the artificial hip joint [J].
Bartz, RL ;
Noble, PC ;
Kadakia, NR ;
Tullos, HS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (09) :1300-1307
[2]
TOTAL HIP-REPLACEMENT IN CONGENITAL DISLOCATION AND DYSPLASIA OF THE HIP [J].
CROWE, JF ;
MANI, VJ ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (01) :15-23
[3]
Effect of superior and superolateral relocations of the hip center on hip joint forces - An experimental and analytical analysis [J].
Doehring, TC ;
Rubash, HE ;
Shelley, FJ ;
Schwendeman, LJ ;
Donaldson, TK ;
Navalgund, YA .
JOURNAL OF ARTHROPLASTY, 1996, 11 (06) :693-703
[4]
Does Radiographic Coxa Profunda Indicate Increased Acetabular Coverage or Depth in Hip Dysplasia? [J].
Fujii, Masanori ;
Nakamura, Tetsuro ;
Hara, Toshihiko ;
Nakashima, Yasuharu ;
Iwamoto, Yukihide .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (06) :2056-2066
[5]
Ganz R, 2007, HIP INT, V17, pS22
[6]
GROSS AE, 1994, CLIN ORTHOP RELAT R, P60
[7]
Hip, knee, and ankle kinematics of high range of motion activities of daily living [J].
Hemmerich, A ;
Brown, H ;
Smith, S ;
Marthandam, SSK ;
Wyss, UP .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (04) :770-781
[8]
Optimal anterior femoral offset for functional range of motion in total hip arthroplasty-a computer simulation study [J].
Hirata, Masanobu ;
Nakashima, Yasuharu ;
Hara, Daisuke ;
Kanazawa, Masayuki ;
Kohno, Yusuke ;
Yoshimoto, Kensei ;
Iwamoto, Yukihide .
INTERNATIONAL ORTHOPAEDICS, 2015, 39 (04) :645-651
[9]
Influencing factors for the increased stem version compared to the native femur in cementless total hip arthroplasty [J].
Hirata, Masanobu ;
Nakashima, Yasuharu ;
Itokawa, Takashi ;
Ohishi, Masanobu ;
Sato, Taishi ;
Akiyama, Mio ;
Hara, Daisuke ;
Iwamoto, Yukihide .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (07) :1341-1346
[10]
Three-dimensional kinetic simulation before and after rotational acetabular osteotomy [J].
Iwai, Shintaro ;
Kabata, Tamon ;
Maeda, Toru ;
Kajino, Yoshitomo ;
Watanabe, Shin ;
Kuroda, Kazunari ;
Fujita, Kenji ;
Hasegawa, Kazuhiro ;
Tsuchiya, Hiroyuki .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2014, 19 (03) :443-450