Fabrication and integration of planar electrodes for contactless conductivity detection on polyester-toner electrophoresis microchips

被引:43
作者
Coltro, Wendell Karlos Tomazelli
Fracassi da Silva, Jose Alberto [2 ]
Carrilho, Emanuel [1 ]
机构
[1] Univ Sao Paulo, Inst Quim Sao Carlos, Grupo Bioanalit Microfabricacao & Separacoes, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Estadual Campinas, Inst Quim, Campinas, SP, Brazil
关键词
direct-printing process; electrochemical detection; microfabrication; toner mask;
D O I
10.1002/elps.200700761
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this report, we describe the microfabrication and integration of planar electrodes for contactless conductivity detection on polyester-toner (PT) electrophoresis microchips using toner masks. Planar electrodes were fabricated by three simple steps: (i) drawing and laser-printing the electrode geometry on polyester films, (ii) sputtering deposition onto substrates, and (iii) removal of toner layer by a lift-off process. The polyester film with anchored electrodes was integrated to PT electrophoresis microchannels by lamination at 120 degrees C in less than 1 min. The electrodes were designed in an antiparallel configuration with 750 mu m width and 750 gm gap between them. The best results were recorded with a frequency of 400 kHz and 10 V-PP using a sinusoidal wave. The analytical performance of the proposed microchip was evaluated by electrophoretic separation of potassium, sodium and lithium in 150 mu m wide x 6 mu m deep microchannels. Under an electric field of 250 V/cm the analytes were successfully separated in less than 90 s with efficiencies ranging from 7000 to 13 000 plates. The detection limits (S/N = 3) found for K+, Na+, and Li+ were 3.1, 4.3, and 7.2 mu mol/L, respectively. Besides the low-cost and instrumental simplicity, the integrated PT chip eliminates the problem of manual alignment and gluing of the electrodes, permitting more robustness and better reproducibility, therefore, more suitable for mass production of electrophoresis microchips.
引用
收藏
页码:2260 / 2265
页数:6
相关论文
共 52 条
[1]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[2]   Fully integrated on-chip electrochemical detection for capillary electrophoresis in a microfabricated device [J].
Baldwin, RP ;
Roussel, TJ ;
Crain, MM ;
Bathlagunda, V ;
Jackson, DJ ;
Gullapalli, J ;
Conklin, JA ;
Pai, R ;
Naber, JF ;
Walsh, KM ;
Keynton, RS .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3690-3697
[3]  
Becker H, 2000, ELECTROPHORESIS, V21, P12, DOI 10.1002/(SICI)1522-2683(20000101)21:1<12::AID-ELPS12>3.0.CO
[4]  
2-7
[5]  
Berthold A, 2002, ELECTROPHORESIS, V23, P3511, DOI 10.1002/1522-2683(200210)23:20<3511::AID-ELPS3511>3.0.CO
[6]  
2-C
[7]   Understanding capacitively coupled contactless conductivity detection in capillary and microchip electrophoresis. Part 1. Fundamentals [J].
Brito-Neto, JGA ;
da Silva, JAF ;
Blanes, L ;
do Lago, CL .
ELECTROANALYSIS, 2005, 17 (13) :1198-1206
[8]   Understanding capacitively coupled contactless conductivity detection in capillary and microchip electrophoresis. Part 2. Peak shape, stray capacitance, noise, and actual electronics [J].
Brito-Neto, JGA ;
da Silva, JAF ;
Blanes, L ;
do Lago, CL .
ELECTROANALYSIS, 2005, 17 (13) :1207-1214
[9]  
Chen Y, 2001, ELECTROPHORESIS, V22, P187, DOI 10.1002/1522-2683(200101)22:2<187::AID-ELPS187>3.0.CO
[10]  
2-0