Automation;
Control;
Human-machine interface design;
PLC based SCADA;
Subsea blowout prevention;
INDUSTRIAL AUTOMATION;
CONTROL PLATFORM;
DESIGN;
IMPLEMENTATION;
FPGAS;
TMR;
D O I:
10.1016/j.isatra.2011.08.003
中图分类号:
TP [自动化技术、计算机技术];
学科分类号:
0812 ;
摘要:
An extremely reliable remote control system for subsea blowout preventer stack is developed based on the off-the-shelf triple modular redundancy system. To meet a high reliability requirement, various redundancy techniques such as controller redundancy, bus redundancy and network redundancy are used to design the system hardware architecture. The control logic, human-machine interface graphical design and redundant databases are developed by using the off-the-shelf software. A series of experiments were performed in laboratory to test the subsea blowout preventer stack control system. The results showed that the tested subsea blowout preventer functions could be executed successfully. For the faults of programmable logic controllers, discrete input groups and analog input groups, the control system could give correct alarms in the human-machine interface. (C) 2011 ISA. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:198 / 207
页数:10
相关论文
共 33 条
[31]
Wang S., 2007, TSINGHUA SCI TECH S1, V12, P116, DOI DOI 10.1016/S1007-0214(07)70095-0
机构:
SW China Normal Univ, Dept Automat, Chongqing 400715, Beibei, Peoples R ChinaSW China Normal Univ, Dept Automat, Chongqing 400715, Beibei, Peoples R China
Zhao, YX
;
Liu, F
论文数: 0引用数: 0
h-index: 0
机构:
SW China Normal Univ, Dept Automat, Chongqing 400715, Beibei, Peoples R ChinaSW China Normal Univ, Dept Automat, Chongqing 400715, Beibei, Peoples R China
机构:
SW China Normal Univ, Dept Automat, Chongqing 400715, Beibei, Peoples R ChinaSW China Normal Univ, Dept Automat, Chongqing 400715, Beibei, Peoples R China
Zhao, YX
;
Liu, F
论文数: 0引用数: 0
h-index: 0
机构:
SW China Normal Univ, Dept Automat, Chongqing 400715, Beibei, Peoples R ChinaSW China Normal Univ, Dept Automat, Chongqing 400715, Beibei, Peoples R China