Validation of a new automated neonatal seizure detection system: A clinician's perspective

被引:46
作者
Cherian, P. J. [1 ]
Deburchgraeve, W. [2 ]
Swarte, R. M. [3 ]
De Vos, M. [2 ,4 ]
Govaert, P. [3 ]
Van Huffel, S. [2 ]
Visser, G. H. [1 ]
机构
[1] Univ Med Ctr, Erasmus MC, Dept Neurol, Clin Neurophysiol Sect, NL-3000 CA Rotterdam, Netherlands
[2] Katholieke Univ Leuven, Dept Elect Engn ESAT, Louvain, Belgium
[3] Univ Med Ctr, Erasmus MC Sophia, Dept Pediat, Sect Neonatol, NL-3000 CA Rotterdam, Netherlands
[4] Carl von Ossietzky Univ Oldenburg, Dept Psychol, Neuropsychol Lab, D-2900 Oldenburg, Germany
关键词
Neonatal seizures; Automated seizure detection; Perinatal asphyxia; HIE; NICU; HYPOXIC-ISCHEMIC ENCEPHALOPATHY; ELECTROGRAPHIC SEIZURES; PROGNOSTIC VALUE; EEG PATTERNS; ELECTROENCEPHALOGRAPHY; DISCHARGES; ASPHYXIA; INFANTS; RISK;
D O I
10.1016/j.clinph.2011.01.043
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To validate an improved automated electroencephalography (EEG)-based neonatal seizure detection algorithm (NeoGuard) in an independent data set. Methods: EEG background was classified into eight grades based on the evolution of discontinuity and presence of sleep-wake cycles. Patients were further sub-classified into two groups; gpI: mild to moderate (grades 1-5) and gpII: severe (grades 6-8) EEG background abnormalities. Seizures were categorised as definite and dubious. Seizure characteristics were compared between gpI and gpII. The algorithm was tested on 756 h of EEG data from 24 consecutive neonates (median 25 h per patient) with encephalopathy and recorded seizures during continuous monitoring (cEEG). No selection was made regarding the quality of EEG or presence of artefacts. Results: Seizure amplitudes significantly decreased with worsening EEG background. Seizures were detected with a total sensitivity of 61.9% (1285/2077). The detected seizure burden was 66,244/97,574 s (67.9%). Sensitivity per patient was 65.9%, with a mean positive predictive value (PPV) of 73.7%. After excluding four patients with severely abnormal EEG background, and predominantly having dubious seizures, the algorithm showed a median sensitivity per patient of 86.9%, PPV of 89.5% and false positive rate of 0.28 h(-1). Sensitivity tended to be better for patients in gpI. Conclusions: The algorithm detects neonatal seizures well, has a good PPV and is suited for cEEG monitoring. Changes in electrographic characteristics such as amplitude, duration and rhythmicity in relation to deteriorating EEG background tend to worsen the performance of automated seizure detection. Significance: cEEG monitoring is important for detecting seizures in the neonatal intensive care unit (NICU). Our automated algorithm reliably detects neonatal seizures that are likely to be clinically most relevant, as reflected by the associated EEG background abnormality. (C) 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1490 / 1499
页数:10
相关论文
共 36 条
[1]   Automated neonatal seizure detection: A multistage classification system through feature selection basedon relevance and redundancy analysis [J].
Aarabi, A ;
Wallois, F ;
Grebe, R .
CLINICAL NEUROPHYSIOLOGY, 2006, 117 (02) :328-340
[2]   Constantly discontinuous EEC patterns in full-term neonates with hypoxic-ischaemic encephalopathy [J].
Biagioni, E ;
Bartalena, L ;
Boldrini, A ;
Pieri, R ;
Cioni, G .
CLINICAL NEUROPHYSIOLOGY, 1999, 110 (09) :1510-1515
[3]   Detection of subclinical electroencephalographic seizure patterns with multichannel amplitude-integrated EEG in full-term neonates [J].
Bourez-Swart, Mireille D. ;
van Rooij, Linda ;
Rizzo, Cristiano ;
de Vries, Linda S. ;
Toet, Mona C. ;
Gebbink, Tineke A. ;
Ezendam, Anja G. J. ;
van Huffelen, Alexander C. .
CLINICAL NEUROPHYSIOLOGY, 2009, 120 (11) :1916-1922
[4]   Outcome of neonates with electrographically identified seizures, or at risk of seizures [J].
Bye, AME ;
Cunningham, CA ;
Chee, KY ;
Flanagan, D .
PEDIATRIC NEUROLOGY, 1997, 16 (03) :225-231
[5]   SPATIAL AND TEMPORAL CHARACTERISTICS OF NEONATAL SEIZURES [J].
BYE, AME ;
FLANAGAN, D .
EPILEPSIA, 1995, 36 (10) :1009-1016
[6]   Technical standards for recording and interpretation of neonatal electroencephalogram in clinical practice [J].
Cherian, Perumpillichira J. ;
Swarte, Renate M. ;
Visser, Gerhard H. .
ANNALS OF INDIAN ACADEMY OF NEUROLOGY, 2009, 12 (01) :58-70
[7]   Automated neonatal seizure detection mimicking a human observer reading EEG [J].
Deburchgraeve, W. ;
Cherian, P. J. ;
De Vos, M. ;
Swarte, R. M. ;
Blok, J. H. ;
Visser, G. H. ;
Govaert, P. ;
Van Huffel, S. .
CLINICAL NEUROPHYSIOLOGY, 2008, 119 (11) :2447-2454
[8]  
DEBURCHGRAEVE W, 2010, THESIS KATHOLIEKE U
[9]   An evaluation of automated neonatal seizure detection methods [J].
Faul, S ;
Boylan, G ;
Connolly, S ;
Marnane, L ;
Lightbody, G .
CLINICAL NEUROPHYSIOLOGY, 2005, 116 (07) :1533-1541
[10]   Automatic seizure detection in the newborn: methods and initial evaluation [J].
Gotman, J ;
Flanagan, D ;
Zhang, J ;
Rosenblatt, B .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 103 (03) :356-362