Soluble manganese(IV); a new chemiluminescence reagent

被引:41
作者
Barnett, NW [1 ]
Hindson, BJ
Lewis, SW
Jones, P
Worsfold, PJ
机构
[1] Deakin Univ, Sch Biol & Chem Sci, Ctr Chiral & Mol Technol, Geelong, Vic 3217, Australia
[2] Univ Plymouth, Dept Environm Sci, Plymouth Environm Res Ctr, Plymouth PL4 8AA, Devon, England
关键词
D O I
10.1039/b106492d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The oxidations of twenty five organic and inorganic species, with solublised manganese(IV), were found to elicit analytically useful chemiluminescence with detection limits (3 x S/N) for Mn(II), Fe(II), morphine and codeine of 5 x 10(-8) M, 2.5 x 10(-7) M, 7.5 x 10(-8) M and 5 x 10(-8) M, respectively. Additionally, the corrected spectra from four different analytes gave wavelengths of maximum emission in the range from 733 nm up to 740 nm suggesting that all these chemiluminescence reactions shared a common emitting species.
引用
收藏
页码:1636 / 1639
页数:4
相关论文
共 18 条
[1]   DETERMINATION OF MORPHINE BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION [J].
ABBOTT, RW ;
TOWNSHEND, A ;
GILL, R .
ANALYST, 1986, 111 (06) :635-640
[2]   Flow methods for the determination of polycyclic aromatic hydrocarbons using low power photomultiplier tube and charge coupled device chemiluminescence detection [J].
Andrew, KN ;
Sanders, MG ;
Forbes, S ;
Worsfold, PJ .
ANALYTICA CHIMICA ACTA, 1997, 346 (01) :113-120
[3]   CHEMI-LUMINESCENCE DETECTION OF THE BENZODIAZEPINE LOPRAZOLAM [J].
ANDREWS, ARJ ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1989, 227 (01) :65-71
[4]   DETERMINATION OF MORPHINE IN-PROCESS STREAMS USING FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION [J].
BARNETT, NW ;
ROLFE, DG ;
BOWSER, TA ;
PATON, TW .
ANALYTICA CHIMICA ACTA, 1993, 282 (03) :551-557
[5]   Some observations on the chemiluminescent reactions of tris(2,2'-bipyridyl)ruthenium(III) with certain Papaver somniferum alkaloids and their derivatives [J].
Barnett, NW ;
Gerardi, RD ;
Hampson, DL ;
Russell, RA .
ANALYTICAL COMMUNICATIONS, 1996, 33 (08) :255-260
[6]   Determination of codeine in process streams using flow-injection analysis with chemiluminescence detection [J].
Barnett, NW ;
Bowser, TA ;
Gerardi, RD ;
Smith, B .
ANALYTICA CHIMICA ACTA, 1996, 318 (03) :309-317
[7]  
Cahiez G, 1995, ENCY REAGENTS ORGANI, P3229
[8]   Acquisition of chemiluminescence spectral profiles using a continuous flow manifold with two dimensional CCD detection [J].
Carretero, AS ;
Fernandez, JR ;
Bowie, AR ;
Worsfold, PJ .
ANALYST, 2000, 125 (03) :387-390
[9]   FLOW-INJECTION CHEMILUMINOMETRIC DETERMINATION OF EPINEPHRINE, NOREPINEPHRINE, DOPAMINE AND L-DOPA [J].
DEFTEREOS, NT ;
CALOKERINOS, AC ;
EFSTATHIOU, CE .
ANALYST, 1993, 118 (06) :627-632
[10]   Analytical applications of tris(2,2′-bipyridyl)ruthenium(III) as a chemiluminescent reagent [J].
Gerardi, RD ;
Barnett, NW ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) :1-41