Modification and benchmarking of MCNP for low-energy tungsten spectra

被引:23
作者
Mercier, JR
Kopp, DT
McDavid, WD
Dove, SB
Lancaster, JL
Tucker, DM
机构
[1] Univ Texas, Hlth Sci Ctr, Radiol Sci Div, San Antonio, TX 78284 USA
[2] Univ Texas, Hlth Sci Ctr, Dent Diagnost Sci Div, San Antonio, TX 78284 USA
[3] Univ Texas, Hlth Sci Ctr, Res Imaging Ctr, San Antonio, TX 78284 USA
关键词
MCNP; Monte Carlo; x-ray spectra; benchmarking;
D O I
10.1118/1.1288397
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The MCNP Monte Carlo radiation transport code was modified for diagnostic medical physics applications. In particular, the modified code was thoroughly benchmarked for the production of polychromatic tungsten x-ray spectra in the 30-150 kV range. Validating the modified code for coupled electron-photon transport with benchmark spectra was supplemented with independent electron-only and photon-only transport benchmarks. Major revisions to the code included the proper treatment of characteristic K x-ray production and scoring, new impact ionization cross sections, and new bremsstrahlung cross sections. Minor revisions included updated photon cross sections, electron-electron bremsstrahlung production, and K x-ray yield. The modified MCNP code is benchmarked to electron backscatter factors, x-ray spectra production, and primary and scatter photon transport. (C) 2000 American Association of Physicists in Medicine. [S0094-2405 (00)00809-9].
引用
收藏
页码:2680 / 2687
页数:8
相关论文
共 44 条
[1]   MONTE-CARLO TECHNIQUES IN MEDICAL RADIATION PHYSICS [J].
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07) :861-920
[2]  
[Anonymous], 1997, UCRL 50400
[3]  
[Anonymous], 1986, NUCL SCI ENG, DOI DOI 10.13182/NSE86-A18182
[4]  
[Anonymous], [No title captured]
[5]   X-RAY-SPECTRA VS ATTENUATION DATA - A THEORETICAL-ANALYSIS [J].
BAIRD, LC .
MEDICAL PHYSICS, 1981, 8 (03) :319-323
[6]   X-RAY-FLUORESCENCE YIELDS, AUGER, AND COSTER-KRONIG TRANSITION PROBABILITIES [J].
BAMBYNEK, W ;
SWIFT, CD ;
CRASEMANN, B ;
FREND, HU ;
RAO, PV ;
PRICE, RE ;
MARK, H ;
FINK, RW .
REVIEWS OF MODERN PHYSICS, 1972, 44 (04) :716-+
[7]  
Berger M.J., 1963, METHODS COMPUT PHYS, P135
[8]   BREMSSTRAHLUNG AND PHOTONEUTRONS FROM THICK TUNGSTEN AND TANTALUM TARGETS [J].
BERGER, MJ ;
SELTZER, SM .
PHYSICAL REVIEW C, 1970, 2 (02) :621-+
[9]   Diagnostic x-ray spectra: A comparison of spectra generated by different computational methods with a measured spectrum [J].
Bhat, M ;
Pattison, J ;
Bibbo, G ;
Caon, M .
MEDICAL PHYSICS, 1998, 25 (01) :114-120
[10]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517