Single-cell microarray for analyzing cellular response

被引:207
作者
Yamamura, S
Kishi, H
Tokimitsu, Y
Kondo, S
Honda, R
Rao, SR
Omori, M
Tamiya, E
Muraguchi, A
机构
[1] Japan Adv Inst Sci & Technol, Sch Mat Sci, Nomi City, Ishikawa 9231292, Japan
[2] Toyama New Ind Org, Toyama 9300866, Japan
[3] Toyama Med & Pharmaceut Univ, Fac Med, Dept Immunol, Sugitani, Toyama 9300194, Japan
关键词
D O I
10.1021/ac0515632
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Detection of cellular response by measuring intracellular calcium, (Ca2+)(i), with Ca2+-dependent fluorescent dye are standard approaches to detect ligand-stimulated cells and to study signaling through ligand/receptor interaction. We describe a single-cell microarray system to analyze cellular response of individual cells such as lymphocytes using microchamber array chips. The single-cell microarray chip is made from polystyrene with over 30 000 microchambers, which can accommodate only single cells. Lymphocytes derived from mouse spleen or human blood were spread on the microarray, and over 80% of the microchambers achieved single-cell status. Stimulation of B-cells through antigen receptors on the microarray allowed us to detect activated B-cells by comparing the states of single B-cells before and after stimulation with antigen, which is disabled for flow cytometry. In addition, this novel method demonstrated retrieval of positive single B-cells from microchambers by a micromanipulator and achieved antibody DNA analysis. The system is suitable for high-throughput analysis of intracellular Ca2+ response at the single-cell level and is applicable to screen antigen-specific lymphocytes for making specific monoclonal antibody.
引用
收藏
页码:8050 / 8056
页数:7
相关论文
共 18 条
[1]  
Akagi Y, 2004, SCI TECHNOL ADV MAT, V5, P343, DOI [10.1016/j.stam.2004.01.011, 10.1016/j.stam.2003.01.011]
[2]   Nanoliter-scale synthesis of arrayed biomaterials and application to human embryonic stem cells [J].
Anderson, DG ;
Levenberg, S ;
Langer, R .
NATURE BIOTECHNOLOGY, 2004, 22 (07) :863-866
[3]   High efficiency creation of human monoclonal antibody-producing hybridomas [J].
Dessain, SK ;
Adekar, SP ;
Stevens, JB ;
Carpenter, KA ;
Skorski, ML ;
Barnoski, BL ;
Goldsby, RA ;
Weinberg, RA .
JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 291 (1-2) :109-122
[4]  
Haugland R.P., 2002, Handbook of Fluorescent Probes and Research Products, V9th
[5]   Transport, location, and quantal release monitoring of single cells on a microfluidic device [J].
Huang, WH ;
Cheng, W ;
Zhang, Z ;
Pang, DW ;
Wang, ZL ;
Cheng, JK ;
Cui, DF .
ANALYTICAL CHEMISTRY, 2004, 76 (02) :483-488
[6]   A METHOD TO ESTABLISH ANTIBODY SECRETING B-CELL LINES AND SIMULTANEOUSLY PERFORM FREQUENCY-ANALYSIS [J].
JINGWU, Z ;
HENDERIKX, P ;
YING, C ;
MEDAER, R ;
RAUS, JCM .
JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 123 (01) :153-154
[7]   Microfluidic selection and retention of a single cardiac myocyte, on-chip dye loading, cell contraction by chemical stimulation, and quantitative fluorescent analysis of intracellular calcium [J].
Li, XJ ;
Li, PCH .
ANALYTICAL CHEMISTRY, 2005, 77 (14) :4315-4322
[8]   Amplification of receptor signalling by Ca2+ entry-mediated translocation and activation of PLCγ2 in B lymphocytes [J].
Nishida, M ;
Sugimoto, K ;
Hara, Y ;
Mori, E ;
Morii, T ;
Kurosaki, T ;
Mori, Y .
EMBO JOURNAL, 2003, 22 (18) :4677-4688
[9]   A three-dimensional flow control concept for single-cell experiments on a microchip. 1. Cell selection, cell retention, cell culture, cell balancing, and cell scanning [J].
Peng, XY ;
Li, PCH .
ANALYTICAL CHEMISTRY, 2004, 76 (18) :5273-5281
[10]  
RAO SR, 2004, P MICRO TOTAL ANAL S, V1, P61