Reproducibility of QT parameters derived from 24-hour ambulatory ECG recordings in healthy subjects

被引:8
作者
Arildsen, H [1 ]
Christiansen, EH [1 ]
Pedersen, AK [1 ]
Molgaard, H [1 ]
机构
[1] Skejby Univ Hosp, Dept Cardiol, Res Unit, DK-8200 Aarhus N, Denmark
关键词
reproducibility; QT interval; QT dynamics; ambulatory ECG recording;
D O I
10.1111/j.1542-474X.2001.tb00082.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: To estimate the reproducibility of QT parameters derived from 24-hour ambulatory ECG recordings. Method: Ten healthy volunteers aged 25 to 41 years participated. In two 24-hour ambulatory ECG recordings obtained 1 day apart, the QT interval was measured manually at stable heart rates in approximately 16 periods during daytime and 6 periods during nighttime. The association between the QT and RR interval was described by linear regression for day and nighttime separately and the following QT parameters were calculated: the QT interval at heart rate 60 beats/min during daytime (QT(60)day), slope(day), slope(night), and the difference in QT(60) between day and nighttime (Delta QT(60)). The QT parameters were assessed four times for each participant to discriminate method inaccuracy from day to day variation. The reproducibility was estimated as the coefficient of repeatability, the relative error, and the ratio between within-subject variability and between-subject variability. Results: The coefficient of repeatability, the relative error and the ratio, respectively, were 19 ms, 1.8% and 0.5 for QT(60)day, 0.076, 21% and 0.68 for slope(day), 0.116, 43% and 1.37 for slope(night), and 37 ms, 325% and 1.19 for Delta QT(60) when estimating the overall day to day reproducibility. inaccuracy of QT measurement accounted for approximately 40% of this variation, whereas the error caused by selecting segments was small. Conclusion: QT(60)day has a high reproducibility and may with advantage replace the conventional QT interval measured on a resting ECG. To assess QT dynamics, the slope of the regression line during daytime is suitable and the short term reproducibility acceptable for clinical trials. Regarding slope(night) and Delta QT(60), the variation is high and the parameters should be used with caution.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 27 条
[21]   QT INTERVAL PROLONGATION PREDICTS CARDIOVASCULAR MORTALITY IN AN APPARENTLY HEALTHY POPULATION [J].
SCHOUTEN, EG ;
DEKKER, JM ;
MEPPELINK, P ;
KOK, FJ ;
VANDENBROUCKE, JP ;
POOL, J .
CIRCULATION, 1991, 84 (04) :1516-1523
[22]   LONG QT SYNDROME PATIENTS WITH MUTATIONS OF THE SCN5A AND HERG GENES HAVE DIFFERENTIAL RESPONSES TO NA+ CHANNEL BLOCKADE AND TO INCREASES IN HEART-RATE - IMPLICATIONS FOR GENE-SPECIFIC THERAPY [J].
SCHWARTZ, PJ ;
PRIORI, SG ;
LOCATI, EH ;
NAPOLITANO, C ;
CANTU, F ;
TOWBIN, JA ;
KEATING, MT ;
HAMMOUDE, H ;
BROWN, AM ;
CHEN, LSK ;
COLATSKY, TJ .
CIRCULATION, 1995, 92 (12) :3381-3386
[23]  
Shimono M., 1999, Annals of Noninvasive Electrocardiology, V4, P176, DOI 10.1111/j.1542-474X.1999.tb00057.x
[24]  
StrambaBadiale M, 1997, EUR HEART J, V18, P1000
[25]  
Tavernier R, 1997, EUR HEART J, V18, P994
[26]   Electrocardiographic repolarization during stress from awakening on alarm call [J].
Toivonen, L ;
Helenius, K ;
Viitasalo, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) :774-779
[27]   QT INTERVALS AT HEART-RATES FROM 50 TO 120 BEATS PER MINUTE DURING 24-HOUR ELECTROCARDIOGRAPHIC RECORDINGS IN 100 HEALTHY-MEN - EFFECTS OF ATENOLOL [J].
VIITASALO, M ;
KARJALAINEN, J .
CIRCULATION, 1992, 86 (05) :1439-1442