Serial volumetric (three-dimensional) intravascular ultrasound analysis of restenosis after directional coronary atherectomy

被引:31
作者
de Vrey, EA
Mintz, GS
von Birgelen, C
Kimura, T
Noboyoshi, M
Popma, JJ
Serruys, PW
Leon, MB
机构
[1] Washington Hosp Ctr, Intravascular Ultrasound Imaging & Cardiac Cathet, Washington, DC USA
[2] Kokura Mem Hosp, Kitakyushu, Fukuoka, Japan
[3] Univ Hosp Dijkzigt, Thoraxctr, NL-3015 GD Rotterdam, Netherlands
关键词
D O I
10.1016/S0735-1097(98)00459-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. We report the use of three dimensional (volumetric) intravascular ultrasound (IVUS) analysis to assess serial changes after directional coronary atherectomy (DCA). Background. Recent serial planar IVUS studies have described a decrease in external elastic membrane (EEM) area following catheter-based intervention as an important mechanism of late lumen renarrowing. Methods. Thirty-one patients with de novo native coronary lesions treated with DCA in the Serial Ultrasound Restenosis (SURE) Trial and in Optimal Atherectomy Restenosis Study (OARS) were enrolled in this study. Serial IVUS was performed before and after intervention and at 6 months' follow-up. In a subgroup of 18 patients from the SURE trial, IVUS was also performed at 24 h and at 1 month postintervention. Segments, 20-mm-long (200 image slices), were analyzed using a previously validated three-dimensional, computerized, automated edge-detection algorithm. The EEM, lumen, and plaque+media (P+M = EEM-lumen) volumes were calculated. Results. At follow up, lumen volume was smaller than at postintervention (159 +/- 69 mm(3) vs. 179 +/- 49 mm(3), p = 0.0003). From postintervention to follow up, there was a decrease in EEM volume (377 +/- 107 to 352 +/- 125 mm(3), p < 0.0001), but no change in P+M volume (p = 0.52). The Delta lumen volume correlated strongly with Delta EEM volume (r = 0.842, p < 0.0001), but not with Delta P+M volume. In the 18 patients from the SURE Trial, the decrease in lumen and EEM volumes occurred late, between 1 month and 6 months of follow up. Conclusions. Volumetric IVUS analysis demonstrated that late lumen volume loss following DCA was a result of a decrease in EEM volume. This was a late event, occurring between 1 and 6 months' postintervention. (J Am Coll Cardiol 1998;32:1874-80) (C) 1998 by the American College of Cardiology.
引用
收藏
页码:1874 / 1880
页数:7
相关论文
共 36 条
  • [1] Andersen HR, 1996, CIRCULATION, V93, P1716
  • [2] INTIMAL PROLIFERATION OF SMOOTH-MUSCLE CELLS AS AN EXPLANATION FOR RECURRENT CORONARY-ARTERY STENOSIS AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY
    AUSTIN, GE
    RATLIFF, NB
    HOLLMAN, J
    TABEI, S
    PHILLIPS, DF
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (02) : 369 - 375
  • [3] Effect of rotational atherectomy in noncalcified atherosclerotic plaque: A volumetric intravascular ultrasound study
    Dussaillant, GR
    Mintz, GS
    Pichard, AD
    Kent, KM
    Satler, LF
    Popma, JJ
    Leon, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (04) : 856 - 860
  • [4] SMALL STENT SIZE AND INTIMAL HYPERPLASIA CONTRIBUTE TO RESTENOSIS - A VOLUMETRIC INTRAVASCULAR ULTRASOUND ANALYSIS
    DUSSAILLANT, GR
    MINTZ, GS
    PICHARD, AD
    KENT, KM
    SATLER, LF
    POPMA, JJ
    WONG, SC
    LEON, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (03) : 720 - 724
  • [5] Accurate three-dimensional reconstruction of intravascular ultrasound data - Spatially correct three-dimensional reconstructions
    Evans, JL
    Ng, KH
    Wiet, SG
    Vonesh, MJ
    Burns, WB
    Radvany, MG
    Kane, BJ
    Davidson, CJ
    Roth, SI
    Kramer, BL
    Meyers, SN
    McPherson, DD
    [J]. CIRCULATION, 1996, 93 (03) : 567 - 576
  • [6] In vivo validation of intravascular ultrasound length measurements using a motorized transducer pullback system
    Fuessl, RT
    Mintz, GS
    Pichard, AD
    Kent, KM
    Satler, LF
    Popma, JJ
    Leon, MB
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (12) : 1115 - &
  • [7] Glantz GA, 1997, PRIMER BIOSTATISTICS, P313
  • [8] ARTERIAL-WALL CHARACTERISTICS DETERMINED BY INTRAVASCULAR ULTRASOUND IMAGING - AN INVITRO STUDY
    GUSSENHOVEN, EJ
    ESSED, CE
    LANCEE, CT
    MASTIK, F
    FRIETMAN, P
    VANEGMOND, FC
    REIBER, J
    BOSCH, H
    VANURK, H
    ROELANDT, J
    BOM, N
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) : 947 - 952
  • [9] HODGSON JM, 1989, INT J CARD IMAGING, V4, P186
  • [10] DIFFERENCES IN COMPENSATORY VESSEL ENLARGEMENT, NOT INTIMAL FORMATION, ACCOUNT FOR RESTENOSIS AFTER ANGIOPLASTY IN THE HYPERCHOLESTEROLEMIC RABBIT MODEL
    KAKUTA, T
    CURRIER, JW
    HAUDENSCHILD, CC
    RYAN, TJ
    FAXON, DP
    [J]. CIRCULATION, 1994, 89 (06) : 2809 - 2815