Removal of methyl isobutyl ketone from contaminated air by trickle-bed air biofilter

被引:23
作者
Cai, ZL [1 ]
Kim, D [1 ]
Sorial, GA [1 ]
机构
[1] Univ Cincinnati, Dept Civil & Environm Engn, Cincinnati, OH 45221 USA
来源
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE | 2005年 / 131卷 / 09期
关键词
D O I
10.1061/(ASCE)0733-9372(2005)131:9(1322)
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A laboratory-scale trickle-bed air biotilter was evaluated for the-removal of methyl isobutyl ketone (MIBK) from. a waste gas stream. Six-.millimeter (6 mm) Celite pellets (R-635) were used as the biological attachment medium. Effects of MIBK volumetric loading rates on removal efficiency, biofilter reacclimation, biomass growth, and removal kinetics were studied under three different operating conditions, namely, backwashing and two intermittent periods (off chemical-no MIBK input; and off flow-no flow input). Backwashing of the biofilter once a week with full-medium fluidization removed the excess biomass and attained stable, long-term performance with over 99% removal efficiency for loading rates less than 3.26, kg "chemical oxygen demand(COD)/m(3) day. The two intermittent periods could also sustain high removal efficiency for loading rates up to 1.09kg COD/m(3) day without any backwashing. The recovery time increased with an increase in loading rates. Furthermore, the intermittent operations required a longer time to recover than backwashing. The pseudo-first-order removal rate constant decreased with an increase in volumetric loading rate. The removal kinetics showed an apparent dependency on the experimental operating conditions.
引用
收藏
页码:1322 / 1329
页数:8
相关论文
共 38 条
[11]   Transient behavior of biofilters: Start-up, carbon balances, and interactions between pollutants [J].
Deshusses, MA .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1997, 123 (06) :563-568
[12]  
Deshusses MA, 1996, BIOTECHNOL BIOENG, V49, P587, DOI 10.1002/(SICI)1097-0290(19960305)49:5&lt
[13]  
587::AID-BIT12&gt
[14]  
3.0.CO
[15]  
2-7
[16]  
DESHUSSES MA, 1995, ENVIRON SCI TECHNOL, V29, P1059, DOI 10.1021/es00004a028
[17]   Development and validation of a simple protocol to rapidly determine the performance of biofilters for VOC treatment [J].
Deshusses, MA ;
Johnson, CT .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (03) :461-467
[18]   BEHAVIOR OF BIOFILTERS FOR WASTE AIR BIOTREATMENT .1. DYNAMIC-MODEL DEVELOPMENT [J].
DESHUSSES, MA ;
HAMER, G ;
DUNN, IJ .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (04) :1048-1058
[19]  
Don J.A., 1984, P S CHAR CONTR OD PO
[20]   Biofiltration of air contaminated by styrene: Effect of nitrogen supply, gas flow rate, and inlet concentration [J].
Jorio, H ;
Bibeau, L ;
Heitz, M .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (09) :1764-1771