Determination of ultratraces of nitrite by solid-phase preconcentration using a novel flow-through spectrophotometric optrode

被引:35
作者
Miró, M
Frenzel, W
Cerdà, V [1 ]
Estela, JM
机构
[1] Univ Balear Isl, Dept Chem, Palma de Mallorca 07071, Spain
[2] Tech Univ Berlin, Inst Tech Umweltschutz, D-10623 Berlin, Germany
关键词
solid-phase extraction; optosensing; preconcentration; nitrite;
D O I
10.1016/S0003-2670(01)00962-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel sorbent-packed planar wall microcolumn-based optosensor coupled to a flow injection analysis system (FIA) for the determination of traces of nitrite by solid-phase spectrophotometry is presented. The methodology is based on the on-line nitrite derivatization with a modified Griess reagent to form an ate-dye whose retention onto octadecyl-covalently bonded silica gel by physical adsorption and partitioning is continuously monitored. After the analytical signal has been recorded, the sorbed compound is eluted with 80% methanol/water (v/v), rendering the system ready for the next extraction. Selection of the solid support and the suitable flow-through cell configuration are discussed in detail. By minimization of the blank signal, a concentration of nitrite as low as 1 ng/ml can be easily determined using 2.5 mi of sample. Detection limit (3 sigma (blank)) of 0.46 ng/ml of nitrite, relative standard deviation better than 4%, sample throughput of 12 h(-1) and an enrichment factor of 93 in relation to the conventional spectrophotometric method were obtained. The utility of the present optosensing system, wherein a mass calibration is also feasible, was testified by the satisfactory results obtained in its application to tap, rain and aquarium water samples. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:55 / 65
页数:11
相关论文
共 35 条
[1]   Fibre-optic pesticide biosensor based on covalently immobilized acetylcholinesterase and thymol blue [J].
Andres, RT ;
Narayanaswamy, R .
TALANTA, 1997, 44 (08) :1335-1352
[2]  
[Anonymous], LAB ROB AUTOM
[3]  
[Anonymous], STAND METH EX WAT WA
[4]  
AYORACANADA MJ, 1999, FRESEN J ANAL CHEM, V363, P59
[5]   Sequential injection sandwich technique for the simultaneous determination of nitrate and nitrite [J].
Cerdà, A ;
Oms, MT ;
Forteza, R ;
Cerdà, V .
ANALYTICA CHIMICA ACTA, 1998, 371 (01) :63-71
[6]   Flow techniques in water analysis [J].
Cerdà, V ;
Estela, JM ;
Forteza, R ;
Cladera, A ;
Becerra, E ;
Altimira, P ;
Sitjar, P .
TALANTA, 1999, 50 (04) :695-705
[7]   COMPARISON OF 2 FIBEROPTIC L-GLUTAMATE BIOSENSORS BASED ON THE DETECTION OF OXYGEN OR CARBON-DIOXIDE, AND THEIR APPLICATION IN COMBINATION WITH FLOW-INJECTION ANALYSIS TO THE DETERMINATION OF GLUTAMATE [J].
DREMEL, BAA ;
SCHMID, RD ;
WOLFBEIS, OS .
ANALYTICA CHIMICA ACTA, 1991, 248 (02) :351-359
[8]   FLOW-INJECTION RENEWABLE FIBER OPTIC SENSOR SYSTEM - PRINCIPLE AND VALIDATION ON SPECTROPHOTOMETRY OF CHROMIUM(VI) [J].
EGOROV, O ;
RUZICKA, J .
ANALYST, 1995, 120 (07) :1959-1962
[9]  
FANG Z, 1993, FLOW INJECTION SEPAR, P97
[10]   APPROACHES TO THE DEVELOPMENT OF SPECTROPHOTOMETRIC REACTION-RATE METHODS BY USE OF IMMOBILIZED ENZYMES IN CONTINUOUS-FLOW SYSTEMS [J].
FERNANDEZROMERO, JM ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1993, 274 (01) :99-107