Pseudocontinuous Arterial Spin Labeling Quantifies Relative Cerebral Blood Flow in Acute Stroke

被引:47
作者
Hernandez, Daymara A. [1 ]
Bokkers, Reinoud P. H. [2 ]
Mirasol, Raymond V. [1 ,4 ]
Luby, Marie [1 ]
Henning, Erica C. [1 ]
Merino, Jose G. [1 ,3 ]
Warach, Steven [1 ]
Latour, Lawrence L. [1 ]
机构
[1] NINDS, NIH, Sect Stroke Diagnost & Therapeut, Bethesda, MD 20892 USA
[2] Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
[3] Johns Hopkins Community Phys, Bethesda, MD USA
[4] NIH, Howard Hughes Med Inst, Res Scholars Program, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
acute stroke; cerebral blood flow; perfusion quantification; ACUTE ISCHEMIC-STROKE; REPERFUSION; INVERSION; THERAPY; DISEASE; TIME; MRI;
D O I
10.1161/STROKEAHA.111.635979
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-The aim of this study was to test whether arterial spin labeling (ASL) can detect significant differences in relative cerebral blood flow (rCBF) in the core, mismatch, and reverse-mismatch regions, and whether rCBF values measured by ASL in those areas differ from values obtained using dynamic susceptibility contrast (DSC) MRI. Methods-Acute stroke patients were imaged with diffusion-weighted imaging (DWI) and perfusion-weighted imaging (ASL and DSC) MRI. An expert reader segmented the ischemic lesion on DWI and the DSC time-to-peak (TTP) maps. Three regions were defined: core (DWI+, TTP+), mismatch (DWI+, TTP+), and reverse-mismatch (DWI+, TTP+). For both ASL and DSC, rCBF maps were created with commercially available software, and the ratio was calculated as the mean signal intensity measured on the side of the lesion to that of the homologous region in the contralateral hemisphere. Values obtained from core, mismatch, and reverse-mismatch were used for paired comparison. Results-Twenty-eight patients were included in the study. The mean age was 65.6 (16.9) years, with a median baseline National Institutes of Health Stroke Scale score of 10 (interquartile range, 4-17). Median time from last known normal to MRI was 5.7 hours (interquartile range, 2.9-22.6). Mean rCBF ratios were significantly higher in the mismatch 0.53 (0.23) versus the core 0.39 (0.33) and reverse-mismatch 0.68 (0.49) versus the core 0.38 (0.35). Differences in rCBF measured with DSC and ASL were not significant. Conclusions-ASL allows for the measurement of rCBF in the core and mismatch regions. Values in the mismatch were significantly higher than in the core, suggesting there is potential salvageable tissue. (Stroke. 2012;43:753-758.)
引用
收藏
页码:753 / 758
页数:6
相关论文
共 29 条
[1]  
ACR Committee on Drugs and Constrast Media, 2010, ACR MAN CONTR MED VE
[2]   Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow [J].
Alsop, DC ;
Detre, JA .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (06) :1236-1249
[3]  
Bokkers RP, 2010, STROKE, V41, pE273
[4]   Arterial spin labeling perfusion MRI at multiple delay times: a correlative study with H215O positron emission tomography in patients with symptomatic carotid artery occlusion [J].
Bokkers, Reinoud P. H. ;
Bremmer, Jochem P. ;
van Berckel, Bart N. M. ;
Lammertsma, Adriaan A. ;
Hendrikse, Jeroen ;
Pluim, Josien P. W. ;
Kappelle, L. Jaap ;
Boellaard, Ronald ;
Klijn, Catharina J. M. .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2010, 30 (01) :222-229
[5]   Magnetic resonance perfusion imaging in acute ischemic stroke using continuous arterial spin labeling [J].
Chalela, JA ;
Alsop, DC ;
Gonzalez-Atavales, JB ;
Maldjian, JA ;
Kasner, SE ;
Detre, JA .
STROKE, 2000, 31 (03) :680-687
[6]   Territorial Arterial Spin Labeling in the Assessment of Collateral Circulation Comparison With Digital Subtraction Angiography [J].
Chng, Soke Miang ;
Petersen, Esben Thade ;
Zimine, Ivan ;
Sitoh, Yih-Yian ;
Lim, C. C. Tchoyoson ;
Golay, Xavier .
STROKE, 2008, 39 (12) :3248-3254
[7]   Continuous Flow-Driven Inversion for Arterial Spin Labeling Using Pulsed Radio Frequency and Gradient Fields [J].
Dai, Weiying ;
Garcia, Dairon ;
de Bazelaire, Cedric ;
Alsop, David C. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) :1488-1497
[8]   PERFUSION IMAGING [J].
DETRE, JA ;
LEIGH, JS ;
WILLIAMS, DS ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :37-45
[9]   Minimizing acquisition time of arterial spin labeling at 3T [J].
Fernandez-Seara, Maria A. ;
Edlow, Brian L. ;
Hoang, Angela ;
Wang, Jiongjiong ;
Feinberg, David A. ;
Detre, John A. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (06) :1467-1471
[10]   Pulsed star labeling of arterial regions (PULSAR): A robust regional perfusion technique for high field imaging [J].
Golay, X ;
Petersen, ET ;
Hui, F .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) :15-21