Determination of Fe(III) and total Fe in wines by sequential injection analysis and flame atomic absorption spectrometry

被引:78
作者
Costa, RCD [1 ]
Araújo, AN [1 ]
机构
[1] Univ Porto, Fac Farm, CEQUP, Dept Quim Fis, P-4050 Porto, Portugal
关键词
SIA/FAAS; Fe(III); total iron; wine;
D O I
10.1016/S0003-2670(01)00845-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The sequential determination of Fe(III) and total Fe in Portuguese table wines by sequential injection analysis (SIA) with flame atomic absorption spectrometry (FAAS) at a sampling rate of 18 samples h(-1) is described. The determination of Fe(m) is based on the extraction with MIBK of the complex formed between Fe(LII) and thiocyanate by using an on-line device for gravimetric analysis previously described for FIA systems, as liquid-liquid extraction module for organic phases less dense than water Afterwards, the determination of total iron is accomplished by sending a small sample aliquot directly to the FAAS nebulizer. The injection of about 1.8 mi of sample enabled the determination of Fe(m) ranging between 0.10-6.00 mg l(-1) The injection of sample volumes of 83, 125, or 333 mul enabled the determination of total iron contents ranging between 1.50-15.00, 0.50-10.00, or 0.25-5.00 mg l(-1), respectively. The Linear regression analysis of the results obtained for the two parameters with the proposed procedure and those provided by the reference methods (colorimetry for Fe(m) and FAAS for total Fe) led to the following relationships: [SIA] = 0.05(+/-0.31) + 0.98(+/-0.10) x [colorim.] for Fe(III) and [SIA] = -0.14(+/-0.29) + 1.03(+/-0.04) x [FAAS] for total Fe. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:227 / 233
页数:7
相关论文
共 25 条
[1]   CONTINUOUS LIQUID-LIQUID-EXTRACTION FOR PRECONCENTRATION WITH ONLINE MONITORING [J].
AGUDO, M ;
RIOS, A ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1993, 65 (20) :2941-2943
[2]   Sequential injection system in flame atomic absorption spectrometry for the determination of calcium and magnesium in mineral waters [J].
Araújo, AN ;
Costa, RCC ;
Lima, JLFC ;
Reis, BF .
ANALYTICA CHIMICA ACTA, 1998, 358 (02) :111-119
[3]   Application of sequential injection analysis to the assay of lead retention characteristics by poly(vinylpyrrolidone):: Trace analysis of lead in waters [J].
Araújo, AN ;
Costa, RCC ;
Lima, JLFC .
ANALYTICAL SCIENCES, 1999, 15 (10) :991-994
[4]   CONTINUOUS SOLVENT-EXTRACTION IN A CLOSED-LOOP SYSTEM [J].
ATALLAH, RH ;
RUZICKA, J ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1987, 59 (24) :2909-2914
[5]  
Bergamin FH, 1978, ANAL CHIM ACTA, V101, P9
[6]   LIQUID LIQUID EXTRACTION IN CONTINUOUS-FLOW SYSTEMS WITHOUT PHASE-SEPARATION [J].
CANETE, F ;
RIOS, A ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1988, 60 (21) :2354-2357
[7]   DETERMINATION OF IRON BY FLOW-INJECTION BASED ON THE CATALYTIC EFFECT OF THE IRON(III) ETHYLENEDIAMINETETRAACETIC ACID COMPLEX ON THE OXIDATION OF HYDROXYLAMINE BY DISSOLVED-OXYGEN [J].
CLADERA, A ;
GOMEZ, E ;
ESTELA, JM ;
CERDA, V .
ANALYST, 1991, 116 (09) :913-917
[8]  
Curvelo-Garcia A.S., 1988, CONTROLO QUALIDADE V
[9]  
Fang Z., 1993, FLOW INJECTION SEPAR
[10]   ANALYTICAL BALANCE AS A DETECTOR IN FLOW-ANALYSIS [J].
JACINTHO, AO ;
ARRUDA, MAZ ;
ZAGATTO, EAG ;
REIS, BF .
ANALYTICA CHIMICA ACTA, 1992, 258 (01) :129-133