Enzyme modified membranes protected by plasma polymer layers

被引:8
作者
Janasek, D
Spohn, U
Kiesow, A
Heilmann, A
机构
[1] Fraunhofer Inst Mech Mat, D-06120 Halle Saale, Germany
[2] Univ Halle Wittenberg, Inst Biotechnol, D-06120 Halle Saale, Germany
关键词
chemiluminescence; peroxidase; hydrogen peroxide detection; plasma polymer category : 6 (biosensors);
D O I
10.1016/S0925-4005(01)00817-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A peroxidase modified membrane was stabilized by thin plasma polymer layer deposited using the monomers allylalcohol or hexamethyldisilazane. In comparison to the uncoated enzyme membrane, there is a significant operational stability improvement of the hydrogen peroxide detection. H2O2 can be detected in the range between 4 and 1000 muM. The sensor is stable for more than 1000 detections under flow injection conditions. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:228 / 231
页数:4
相关论文
共 17 条
[1]   Improved operational stability of biosensors based on enzyme-polyelectrolyte complex adsorbed into a porous carbon electrode [J].
Gavalas, VG ;
Chaniotakis, NA ;
Gibson, TD .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (11) :1205-1211
[2]   EXTENDED SHELF-LIFE OF ENZYME-BASED BIOSENSORS USING A NOVEL STABILIZATION SYSTEM [J].
GIBSON, TD ;
HULBERT, JN ;
PARKER, SM ;
WOODWARD, JR ;
HIGGINS, IJ .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (10) :701-708
[3]   MEDIATOR-MODIFIED ELECTRODES FOR ELECTROCATALYTIC OXIDATION OF NADH [J].
GRUNDIG, B ;
WITTSTOCK, G ;
RUDEL, U ;
STREHLITZ, B .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 395 (1-2) :143-157
[4]   CHANGES OF THE OPTICAL AND ELECTRICAL-PROPERTIES OF PLASMA POLYMER-METAL COMPOSITE FILMS DURING THERMAL ANNEALING [J].
HEILMANN, A ;
WERNER, J ;
STENZEL, O ;
HOMILIUS, F .
THIN SOLID FILMS, 1994, 246 (1-2) :77-85
[5]  
HINTSCHE R, 1990, Patent No. 3927056
[6]   THE INFLUENCE OF THE POLYMER MATRIX ON THE PROPERTIES AND THE STRUCTURE OF PLASMA POLYMER SILVER COMPOSITE FILMS [J].
HOMILIUS, F ;
HEILMANN, A ;
WERNER, J ;
GRUNEWALD, W .
PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1993, 137 (01) :145-154
[7]   Chemiluminometric Flow Injection Analysis procedures for the enzymatic determination of L-alanine, α-ketoglutarate and L-glutamate [J].
Janasek, D ;
Spohn, U .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (02) :123-129
[8]   Thin-film microbiosensors for glucose-lactate monitoring [J].
Jobst, G ;
Moser, I ;
Varahram, M ;
Svasek, P ;
Aschauer, E ;
Trajanoski, Z ;
Wach, P ;
Kotanko, P ;
Skrabal, F ;
Urban, G .
ANALYTICAL CHEMISTRY, 1996, 68 (18) :3173-3179
[9]   MECHANICAL FAILURE IN THIN-FILM NONLINEAR-OPTICAL POLYMERS - STRUCTURE AND PROCESSING ISSUES [J].
MCCULLOCH, I ;
MAN, HT ;
SONG, K ;
YOON, H .
JOURNAL OF APPLIED POLYMER SCIENCE, 1994, 53 (05) :665-676
[10]   AMPEROMETRIC ENZYME ELECTRODES FOR LACTATE AND GLUCOSE DETERMINATIONS IN HIGHLY DILUTED AND UNDILUTED MEDIA [J].
PFEIFFER, D ;
SCHELLER, FW ;
SETZ, K ;
SCHUBERT, F .
ANALYTICA CHIMICA ACTA, 1993, 281 (03) :489-502