Comparison of bone densitometry of the phalanges, distal forearm and axial skeleton in early postmenopausal women participating in the EPIC study

被引:31
作者
Ravn, P
Overgaard, K
Huang, C
Ross, PD
Green, D
McClung, M
机构
[1] HAWAII OSTEOPOROSIS CTR,HONOLULU,HI
[2] CITY HOSP NOTTINGHAM,BONE & MINERAL UNIT,NOTTINGHAM,ENGLAND
[3] OSTEOPOROSIS RES CTR,PORTLAND,OR
关键词
DXA; postmenopausal women; premenopausal women; radiographic absorptiometry of the phalanges; SXA;
D O I
10.1007/BF01623390
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We present baseline bone densitometry from the Early Postmenopausal Interventional Cohort study (EPIC, sponsored by Merck, Sharp & Dohme) for the first time, in which 1609 women from England, Oregon, Hawaii and Denmark are participating to investigate the efficacy of daily oral alendronate to prevent early postmenopausal bone lass. We compared radiographic absorptiometry (RA) of the phalanges for bone mineral density (BMD) measurement with single-energy X-ray absorptiometry (SXA) of the distal forearm, and dual-energy X-ray absorptiometry (DSA) of the lumbar spine, proximal femur and distal forearm, In a random subgroup of 308 women, aged 45-60 years, on average 6 years since menopause (YSM), bone densitometry was measured once at baseline by Rbi of the phalanges besides the mandatory measurements by DXA. Bone densitometry was furthermore measured by SSA al the Danish site (89 women). Sixty-eight of the women had duplicate measurements performed within 1-3 weeks to evaluate the short-term precision error (CV%). One. hundred and one healthy premenopausal women, aged 25-48 years, were recruited at the Danish and Hawaiian sites to establish a reference group, The precision error was 1.5% for RA of the phalanges and in the range 1.0-2.2% for SXA and DXA, BMD by RA correlated with BMD measured by SXA and DXA in the range 0.45<r<0.72 (p<0.001). In conclusion, bone densitometry by RA of the phalanges is highly correlated with bone densitometry by SXA and DXA, RA of the phalanges has a short-term precision error comparable to that of SXA and DXA.
引用
收藏
页码:308 / 313
页数:6
相关论文
共 36 条
[1]  
ADAMS J, 1994, J BONE MINER RES S1, V9, pS129
[2]  
[Anonymous], [No title captured]
[3]  
BARNETT E, 1960, Clin Radiol, V11, P166, DOI 10.1016/S0009-9260(60)80012-8
[4]   SINGLE X-RAY ABSORPTIOMETRY - PERFORMANCE-CHARACTERISTICS AND COMPARISON WITH SINGLE-PHOTON ABSORPTIOMETRY [J].
BORG, J ;
MOLLGAARD, A ;
RIIS, BJ .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (05) :377-381
[5]  
COLBERT C, 1969, CLIN ORTHOP RELAT R, V65, P39
[6]   RADIOGRAPHIC ABSORPTIOMETRY - A SIMPLE METHOD FOR DETERMINATION OF BONE MASS [J].
COSMAN, F ;
HERRINGTON, B ;
HIMMELSTEIN, S ;
LINDSAY, R .
OSTEOPOROSIS INTERNATIONAL, 1991, 2 (01) :34-38
[7]   BONE-DENSITY AT VARIOUS SITES FOR PREDICTION OF HIP-FRACTURES [J].
CUMMINGS, SR ;
BLACK, DM ;
NEVITT, MC ;
BROWNER, W ;
CAULEY, J ;
ENSRUD, K ;
GENANT, HK ;
PALERMO, L ;
SCOTT, J ;
VOGT, TM .
LANCET, 1993, 341 (8837) :72-75
[8]   ARE PATIENTS WITH HIP-FRACTURES MORE OSTEOPOROTIC - REVIEW OF THE EVIDENCE [J].
CUMMINGS, SR .
AMERICAN JOURNAL OF MEDICINE, 1985, 78 (03) :487-494
[9]   PREDICTING VARIOUS FRAGILITY FRACTURES IN WOMEN BY FOREARM BONE DENSITOMETRY - A FOLLOW-UP-STUDY [J].
GARDSELL, P ;
JOHNELL, O ;
NILSSON, BE ;
GULLBERG, B .
CALCIFIED TISSUE INTERNATIONAL, 1993, 52 (05) :348-353
[10]   APPROPRIATE USE OF BONE DENSITOMETRY [J].
GENANT, HK ;
BLOCK, JE ;
STEIGER, P ;
GLUEER, CC ;
ETTINGER, B ;
HARRIS, ST .