Skin temperature changes and changes in skin blood flow monitored with laser Doppler flowmetry and imaging: A methodological study in normal humans

被引:33
作者
Bornmyr, S
Svensson, H
Lilja, B
Sundkvist, G
机构
[1] MALMO UNIV HOSP, DEPT CLIN PHYSIOL, MALMO, SWEDEN
[2] MALMO UNIV HOSP, DEPT PLAST & RECONSTRUCT SURG, MALMO, SWEDEN
[3] MALMO UNIV HOSP, DEPT ENDOCRINOL, MALMO, SWEDEN
来源
CLINICAL PHYSIOLOGY | 1997年 / 17卷 / 01期
关键词
cooling; indirect heating; laser Doppler flowmetry; laser Doppler imaging; skin blood flow; temperature;
D O I
10.1046/j.1365-2281.1997.01313.x
中图分类号
Q4 [生理学];
学科分类号
071003 [生理学];
摘要
The aim of the present study was to elucidate the interrelation between changes in skin temperature and changes in skin blood flow, as measured by laser Doppler techniques. Therefore, 17 healthy volunteers were studied upon immersion of both feet in water of 15 degrees C for 10 min followed by body warming for 30 min. Measurements using laser Doppler flowmetry (LDF) were performed from the nailfold of the big toe, while measurements using laser Doppler imaging (LDI) were performed from the dorsum of the foot. Temperatures were recorded simultaneously from the toe tip and the dorsal foot skin. Temperatures at the toe tip were significantly lower than at the dorsal foot skin. Cooling caused decreased values in all parameters, with restitution during indirect heating. There was an exponential interrelation between LDF and temperature readings from the toe owing to very high LDF values at the end of indirect heating. On the dorsum of the foot, relative changes in LDI and temperature showed a linear relationship (r(s)=0.65), although LDI values were consistently higher than temperatures. It is concluded that temperature readings constitute an ambiguous measure of skin blood flow. On the toe tip, blood flow through opened arteriovenous shunts during indirect heating does not correlate with temperature. Cooling of the foot decreases skin temperature, mainly by heat conduction, whereas skin blood flow is only slightly reduced.
引用
收藏
页码:71 / 81
页数:11
相关论文
共 14 条
[1]
THE OPTICS OF HUMAN-SKIN [J].
ANDERSON, RR ;
PARRISH, JA .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1981, 77 (01) :13-19
[2]
NITRIC-OXIDE - MEDIATOR, MURDERER, AND MEDICINE [J].
ANGGARD, E .
LANCET, 1994, 343 (8907) :1199-1206
[3]
THERMOGRAPHY AND LASER DOPPLER FLOWMETRY FOR MONITORING CHANGES IN FINGER SKIN BLOOD-FLOW UPON CIGARETTE-SMOKING [J].
BORNMYR, S ;
SVENSSON, H .
CLINICAL PHYSIOLOGY, 1991, 11 (02) :135-141
[4]
CASPARY L, 1988, INT J MICROCIRC, V7, P367
[5]
A LASER DOPPLER SCANNER FOR IMAGING BLOOD-FLOW IN SKIN [J].
ESSEX, TJH ;
BYRNE, PO .
JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (03) :189-194
[6]
PREDICTION OF SAMPLING DEPTH AND PHOTON PATHLENGTH IN LASER-DOPPLER FLOWMETRY [J].
JAKOBSSON, A ;
NILSSON, GE .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (03) :301-307
[7]
LASER-DOPPLER MEASUREMENT OF SKIN BLOOD-FLOW - COMPARISON WITH PLETHYSMOGRAPHY [J].
JOHNSON, JM ;
TAYLOR, WF ;
SHEPHERD, AP ;
PARK, MK .
JOURNAL OF APPLIED PHYSIOLOGY, 1984, 56 (03) :798-803
[8]
EVALUATION OF A LASER DOPPLER FLOWMETER FOR MEASUREMENT OF TISSUE BLOOD-FLOW [J].
NILSSON, GE ;
TENLAND, T ;
OBERG, PA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (10) :597-604
[9]
SIGNAL PROCESSOR FOR LASER DOPPLER TISSUE FLOWMETERS [J].
NILSSON, GE .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1984, 22 (04) :343-348
[10]
COMPARISON OF LASER-DOPPLER PERFUSION IMAGING, LASER-DOPPLER FLOWMETRY, AND THERMOGRAPHIC IMAGING FOR ASSESSMENT OF BLOOD-FLOW IN HUMAN SKIN [J].
SEIFALIAN, AM ;
STANSBY, G ;
JACKSON, A ;
HOWELL, K ;
HAMILTON, G .
EUROPEAN JOURNAL OF VASCULAR SURGERY, 1994, 8 (01) :65-69