Wavelet based automatic seizure detection in intracerebral electroencephalogram

被引:263
作者
Khan, YU
Gotman, J
机构
[1] McGill Univ, Montreal Neurol Inst, Montreal, PQ H3A 2B4, Canada
[2] McGill Univ, Dept Neurol & Neurosurg, Montreal, PQ H3A 2B4, Canada
基金
加拿大健康研究院;
关键词
epilepsy; automatic seizure detection; electroencephalogram; discrete wavelet transform;
D O I
10.1016/S1388-2457(03)00035-X
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Automatic seizure detection is often used during long-term monitoring, and is particularly important during intracerebral investigations. Existing methods make many false detections, particularly in intracerebral electroencephalogram (EEG) because of frequent large amplitude rhythmic activity bursts that are non-epileptiform. Objective: To develop a seizure detection method for intracerebral monitoring that is as sensitive as existing methods but has fewer false detections. Methods: To capture the rhythmic nature of seizure discharges, we developed a wavelet-based method, examining how different frequency ranges fluctuate compared to the background. In particular, the system remembers rhythmic bursts occurring commonly in the background to avoid detecting them as seizures. Results: The method was evaluated on test data from 11 patients, including 229 h and 66 seizures, and its performance compared to the method of Gotman (Electroencephalogr clin Neurophysiol 76 (1990) 317). Detection sensitivity was unchanged at close to 90%, but false detections were reduced from 2.4 to 0.3/h. Conclusions: Perfect sensitivity is unlikely because the morphology of seizure discharges is so variable. Nevertheless, the 87% sensitivity obtained in the combined training and testing data is quite high. We reduced the average false alarm rate to one per 3 h of recording, or 6 per 24-h period. Given how rapidly one can decide visually that a detection is erroneous, false detections should not cause any burden to the reviewer. Significance: In intracerebral EEG it is possible to detect seizures automatically with high sensitivity and high specificity. (C) 2003 International Federation of Clinical Neurophysiology. Published by Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:898 / 908
页数:11
相关论文
共 18 条
[1]  
[Anonymous], CBMS NSF REGIONAL C
[2]   Patient awareness of seizures [J].
Blum, DE ;
Eskola, J ;
Bortz, JJ ;
Fisher, RS .
NEUROLOGY, 1996, 47 (01) :260-264
[3]  
Burrus C.S., 1998, introduction to Wavelets and Wavelet Transforms-A Primer
[4]  
Gabor AJ, 1996, ELECTROEN CLIN NEURO, V99, P257, DOI 10.1016/0013-4694(96)96001-0
[5]   Seizure detection using a self-organizing neural network: validation and comparison with other detection strategies [J].
Gabor, AJ .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 107 (01) :27-32
[6]   AUTOMATIC RECOGNITION AND QUANTIFICATION OF INTERICTAL EPILEPTIC ACTIVITY IN HUMAN SCALP EEG [J].
GOTMAN, J ;
GLOOR, P .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1976, 41 (05) :513-529
[7]   AUTOMATIC RECOGNITION OF EPILEPTIC SEIZURES IN THE EEG [J].
GOTMAN, J .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1982, 54 (05) :530-540
[8]   AUTOMATIC SEIZURE DETECTION - IMPROVEMENTS AND EVALUATION [J].
GOTMAN, J .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1990, 76 (04) :317-324
[9]   AN AUTOMATED SEIZURE MONITORING-SYSTEM FOR PATIENTS WITH INDWELLING RECORDING ELECTRODES [J].
HARDING, GW .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1993, 86 (06) :428-437
[10]   WAVELET PREPROCESSING FOR AUTOMATED NEURAL-NETWORK DETECTION OF EEG SPIKES [J].
KALAYCI, T ;
OZDAMAR, O .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1995, 14 (02) :160-166