Renal angioplasty and stenting with distal protection of the main renal artery in ischemic nephropathy: Early experience

被引:84
作者
Holden, A
Hill, A
机构
[1] Auckland Hosp, Dept Radiol, Auckland, New Zealand
[2] Auckland Hosp, Dept Vasc Surg, Auckland, New Zealand
关键词
D O I
10.1016/S0741-5214(03)00606-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: We present a retrospective review of a single tertiary hospital experience in renal artery stent revascularization with distal protection in patients with ischemic nephropathy. The objectives of the study included preliminary assessment of the effect of distal protection on procedure-related acute deterioration in renal function and on renal salvage. Material and methods: All patients had significant atherosclerotic main renal artery stenosis, documented at preprocedural imaging, and a degree of chronic renal impairment before revascularization. Forty-six renal arteries were treated in 37 patients with preprocedural renal impairment, which was mild in 10 patients, moderate in 19 patients, and severe in 8 patients. Median patient age was 72 years (range, 59-85 years). All patients underwent primary stenting of renal artery ostial stenoses with adjuvant use of a filter device (Angioguard guide wire system; Cordis Corp, Division of Johnson & Johnson, Miami, Fla) in the distal main renal artery. The filter baskets were recaptured for pathologic analysis. Results: Overall, in 95% of patients, including all patients with preprocedural mild or moderate renal impairment, renal function was stabilized or improved after revascularization. In 5% of patients decline in renal function was unchanged. No patients had acute postprocedural deterioration. Mean follow-up was 12.5 months (range, 2-28 months). These results are better than in most reports in the literature and also better than in a historical group of similar patients with ischemic nephropathy who underwent stent revascularization without distal protection at the same institution. The improved results are thought to be due to prevention of cholesterol atheroembolization during the procedure by the distal filter baskets. Sixty-five percent of the distal protection baskets contained embolic material, including fresh thrombus, chronic thrombus, atheromatous fragments, and cholesterol clefts. Conclusion: A distal protection device may significantly improve results during stent revascularization. There are a number of unique demands on a renal protection device, and the ideal device has not yet been developed.
引用
收藏
页码:962 / 968
页数:7
相关论文
共 42 条
[1]  
Bloch MJ, 2000, SEMIN NEPHROL, V20, P474
[2]   Treatment of ostial renal-artery stenoses with vascular endoprostheses after unsuccessful balloon angioplasty [J].
Blum, U ;
Krumme, B ;
Flugel, P ;
Gabelmann, A ;
Lehnert, T ;
BuitragoTellez, C ;
Schollmeyer, P ;
Langer, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (07) :459-465
[3]   Treatment of renal angioplasty failure by percutaneous renal artery stenting with Palmaz stents: Midterm technical and clinical results [J].
Boisclair, C ;
Therasse, E ;
Oliva, VL ;
Soulez, G ;
Bui, BT ;
Querin, S ;
Robillard, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (01) :245-251
[4]   Artifact-free in-stent lumen visualization by standard magnetic resonance angiography using a new metallic magnetic resonance imaging stent [J].
Buecker, A ;
Spuentrup, E ;
Ruebben, A ;
Günther, RW .
CIRCULATION, 2002, 105 (15) :1772-1775
[5]   Endovascular revascularization of renal artery stenosis: Technical and clinical results [J].
Bush, RL ;
Najibi, S ;
MacDonald, J ;
Lin, PH ;
Chaikof, EL ;
Martin, LG ;
Lumsden, AB .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (05) :1041-1049
[6]  
CASSIFY JD, 1992, OXFORD TXB CLIN NEPH, P1158
[7]   EVOLUTION OF RENAL-INSUFFICIENCY IN ISCHEMIC NEPHROPATHY [J].
DEAN, RH ;
TRIBBLE, RW ;
HANSEN, KJ ;
ONEIL, E ;
CRAVEN, TE ;
REDDING, JF .
ANNALS OF SURGERY, 1991, 213 (05) :446-456
[8]   FLASH PULMONARY-EDEMA AND THE DIAGNOSTIC SUSPICION OF OCCULT RENAL-ARTERY STENOSIS [J].
DIAMOND, JR .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1993, 21 (03) :328-330
[9]  
GAINES PA, 1988, LANCET, V1, P168
[10]   Suprarenal aortic cross-clamping in elective abdominal aortic aneurysm surgery [J].
Giulini, SM ;
Bonardelli, S ;
Portolani, N ;
Giovanetti, M ;
Galvani, G ;
Maffeis, R ;
Coniglio, A ;
Tiberio, GAM ;
Nodari, F ;
De Lucia, M ;
Lussardi, L ;
Regina, P ;
Scolari, F ;
Tomasoni, G .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 20 (03) :286-289