Artifact-free in-stent lumen visualization by standard magnetic resonance angiography using a new metallic magnetic resonance imaging stent

被引:43
作者
Buecker, A [1 ]
Spuentrup, E [1 ]
Ruebben, A [1 ]
Günther, RW [1 ]
机构
[1] Univ Technol Aachen, Clin Diagnost Radiol, D-52057 Aachen, Germany
关键词
magnetic resonance imaging; angiography; stents;
D O I
10.1161/01.CIR.0000015852.60212.DB
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Metallic stents cause susceptibility and radiofrequency artifacts on MR images, which, up to now, have not allowed for complete visualization of the stent lumen by MR angiography. The aim of this study was to investigate the potential of a new dedicated renal MRI stent for artifact-free in-stent lumen visualization in vitro and in a swine model. Methods and Results-In vitro investigations were performed with prototypes of balloon-expandable Aachen Resonance Renal MRI Stents dilated to diameters of 3 to 6 mm and placed in an aqueous gadolinium solution (1:25). Phase-contrast and contrast-enhanced T-1-weighted gradient echo images were acquired. Renal MRI stents (n=12) were deployed in the renal arteries of 6 pigs. Renal arteries were examined with phase-contrast angiography and with flow measurements before and after stent placement in the stented area, respectively. Additionally, a contrast-enhanced, T-1-weighted, spoiled-gradient echo sequence after administration of 0.2 mmol gadolinium-DTPA/k,, body weight was performed after stent placement. The visibility of artifacts was analyzed on in vitro and in vivo images by two investigators who knew the stent positions. Stent positions were determined visually (in vitro) or by x-ray angiography (animal experiments). No artifacts were detected independent of the applied imaging sequence and the stent orientation to the main magnetic field. Conclusion-The examined prototypes of fully MR-compatible MRI stents allow artifact-free visualization of the stent lumen with phase-contrast and contrast-enhanced T-1-weighted angiography, as well as phase-contrast flow measurements in the stented area.
引用
收藏
页码:1772 / 1775
页数:4
相关论文
共 13 条
[1]   MR imaging of vascular stents: effects of susceptibility, flow, and radiofrequency eddy currents [J].
Bartels, LW ;
Smits, HFM ;
Bakker, CJG ;
Viergever, MA .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (03) :365-371
[2]  
HAAN MW, 1996, RADIOLOGY, V198, P449
[3]   Three-dimensional contrast-enhanced MR angiography sf endovascular covered stents in patients with peripheral arterial occlusive disease [J].
Juergens, KU ;
Tombach, B ;
Reimer, P ;
Vestring, T ;
Heindel, W .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) :1299-1303
[4]   The active magnetic resonance imaging stent (AMRIS) - Initial experimental in vivo results with locally amplified MR angiography and flow measurements [J].
Kivelitz, D ;
Wagner, S ;
Hansel, J ;
Schnorr, J ;
Wetzler, R ;
Busch, M ;
Melzer, A ;
Taupitz, M ;
Hamm, B .
INVESTIGATIVE RADIOLOGY, 2001, 36 (11) :625-631
[5]  
Klemm T, 2000, J MAGN RESON IMAGING, V12, P606, DOI 10.1002/1522-2586(200010)12:4<606::AID-JMRI14>3.0.CO
[6]  
2-J
[7]   Sequential magnetic resonance monitoring of pulmonary flow with endovascular stents placed across the pulmonary valve in growing swine [J].
Kuehne, T ;
Saeed, M ;
Reddy, G ;
Akbari, H ;
Gleason, K ;
Turner, D ;
Teitel, D ;
Moore, P ;
Higgins, CB .
CIRCULATION, 2001, 104 (19) :2363-2368
[8]   Stent appearance at contrast-enhanced MR Angiography:: In vitro examination with 14 stents [J].
Lenhart, M ;
Völk, M ;
Manke, C ;
Nitz, WR ;
Strotzer, M ;
Feuerbach, S ;
Link, J .
RADIOLOGY, 2000, 217 (01) :173-178
[9]  
Lethimonnier F, 1999, JMRI-J MAGN RESON IM, V10, P899, DOI 10.1002/(SICI)1522-2586(199911)10:5<899::AID-JMRI40>3.0.CO
[10]  
2-1