Use of isotope differential derivatization for simultaneous determination of thiols and oxidized thiols by liquid chromatography tandem mass spectrometry

被引:95
作者
Huang, Yun-Qing [1 ]
Ruan, Ge-Deng [1 ]
Liu, Jia-Qi [1 ]
Gao, Qiang [1 ]
Feng, Yu-Qi [1 ]
机构
[1] Wuhan Univ, Dept Chem, Minist Educ, Key Lab Analyt Chem Biol & Med, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
Isotope differential derivatization; Thiols; Oxidized thiols; Urine; OXIDATIVE STRESS; GLUTATHIONE; DISULFIDES; REDOX; ELECTROSPRAY; HOMOCYSTEINE; ENHANCEMENT; METABOLISM; MECHANISMS; CYSTEINE;
D O I
10.1016/j.ab.2011.05.020
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Here we report a new isotopic pair of derivatization reagents, omega-bromoacetonylquinolinium bromide (BQB) and d(7)-omega-bromoacetonylquinolinium bromide (d(7)-BQB). BQB and d(7)-BQB both rapidly and selectively reacted with thiols in acidic medium within 3 min with the aid of a microwave. Reduced thiols and total thiols in urine were labeled with BQB and d(7)-BQB, respectively. The BQB- and d(7)-BQB-labeled urine samples were then mixed and separated on a HILIC (hydrophilic interaction chromatography) column followed by electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection. The new strategy, which we have named isotope differential derivatization, allows us to simultaneously determine thiols and oxidized thiols in a single run. Compared with positive mode ESI detection of unlabeled thiols, the positive mode ESI-MS signal intensities of BQB-labeled thiols were found to increase by 10-, 20-, and 40-fold for cysteine (Cys), homocysteine (HCys), and glutathione (GSH), respectively (unlabeled N-acetylcysteine (Nac) is difficult to detect by ESI-MS in positive mode due to its low ionization efficiency). The detection limits calculated at a signal-to-noise ratio of 3 were found to be 8.02, 1.56, 0.833, and 3.27 nmol/L for Cys, HCys, Nac, and GSH, respectively. Recoveries of thiols and disulfides from spiked urine samples were between 80% and 105%. The method was successfully used to determine thiols and oxidized thiols in urine samples of 25 healthy volunteers. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 41 条
[1]
Ion suppression in mass spectrometry [J].
Annesley, TM .
CLINICAL CHEMISTRY, 2003, 49 (07) :1041-1044
[2]
Improved Sensitivity Mass Spectrometric Detection of Eicosanoids by Charge Reversal Derivatization [J].
Bollinger, James G. ;
Thompson, Wallace ;
Lai, Ying ;
Oslund, Rob C. ;
Hallstrand, Teal S. ;
Sadilek, Martin ;
Turecek, Frantisek ;
Gelb, Michael H. .
ANALYTICAL CHEMISTRY, 2010, 82 (16) :6790-6796
[3]
Bremer HJ., 1981, Disturbances of Amino Acid Metabolism
[4]
Oxidative damage and protection of the RPE [J].
Cai, JY ;
Nelson, KC ;
Wu, M ;
Sternberg, P ;
Jones, DP .
PROGRESS IN RETINAL AND EYE RESEARCH, 2000, 19 (02) :205-221
[5]
Analytical methods to investigate glutathione and related compounds in biological and pathological processes [J].
Camera, E ;
Picardo, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 781 (1-2) :181-206
[6]
Oxidative stress and heart disease: Cardiac dysfunction, nutrition, and gene therapy [J].
Cantor, EJF ;
Mancini, EV ;
Seth, R ;
Yao, XH ;
Netticadan, T .
CURRENT HYPERTENSION REPORTS, 2003, 5 (03) :215-220
[7]
Comprehensive Plasma Thiol Redox Status Determination for Metabolomics [J].
D'Agostino, Lisa A. ;
Lam, Karen P. ;
Lee, Richard ;
Britz-McKibbin, Philip .
JOURNAL OF PROTEOME RESEARCH, 2011, 10 (02) :592-603
[8]
Development of a Selective ESI-MS Derivatization Reagent: Synthesis and Optimization for the Analysis of Aldehydes in Biological Mixtures [J].
Eggink, Mark ;
Wijtmans, Maikel ;
Ekkebus, Reggy ;
Lingeman, Henk ;
de Esch, Iwan J. P. ;
Kool, Jeroen ;
Niessen, Wilfried M. A. ;
Irth, Hubertus .
ANALYTICAL CHEMISTRY, 2008, 80 (23) :9042-9051
[9]
A review of specific dietary antioxidants and the effects on biochemical mechanisms related to neurodegenerative processes [J].
Esposito, E ;
Rotilio, D ;
Di Matteo, V ;
Di Giulio, C ;
Cacchio, M ;
Algeri, S .
NEUROBIOLOGY OF AGING, 2002, 23 (05) :719-735
[10]
Sensitivity enhancement in liquid chromatography/atmospheric pressure ionization mass spectrometry using derivatization and mobile phase additives [J].
Gao, SM ;
Zhang, ZP ;
Karnes, HT .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 825 (02) :98-110