Effects of a clinical trial on mechanical ventilation practices in patients with acute lung injury

被引:82
作者
Checkley, William [1 ]
Brower, Roy [1 ]
Korpak, Anna [2 ]
Thompson, B. Taylor [2 ]
机构
[1] Johns Hopkins Univ, Div Pulm & Crit Care, Sch Med, Baltimore, MD 21205 USA
[2] Massachusetts Gen Hosp, Dept Med, Pulm & Crit Care Unit, Boston, MA 02114 USA
关键词
acute lung injury; mechanical ventilation; clinician practices;
D O I
10.1164/rccm.200709-1424OC
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Rationale: In a clinical trial by the Acute Respiratory Distress Syndrome Network (ARDSNet), mechanical ventilation with tidal volumes of 6 ml/kg decreased mortality from acute lung injury. However, interpretations of these results generated controversy and it was unclear if this trial would change usual-care practices. Objectives: First, to determine if clinical practices at ARDSNet hospitals changed after the tidal volume trial. Second, to determine if tidal volume and plateau pressure (Pplat) within 48 hours before randomization affected hospital mortality in patients subsequently managed with 6 ml/kg predicted body weight (PBW). Methods: We used preenrollment data from 2,451 patients enrolled in six trials (1996-2005) to describe changes in tidal volume over time. We used logistic regression to determine if preenrollment tidal volume or Pplat affected mortality. Measurements and Main Results: Median preenrollment tidal volume decreased from 10.3 ml/kg PBW (range, 4.3-17.1) during the tidal volume trial (1996-1999) to 7.3 ml/kg PBW (range, 3.9-16.2) after its completion (P < 0.001). Preenrollment tidal volume was not associated with mortality (P = 0.566). The odds of death increased multiplicatively with each cm H2O of preenrollment Pplat (P< 0.001) (e.g., the odds of death was 1.37 times greater when preenrollment Pplat increased by 10 cm H2O). Conclusions: Physicians used lower tidal volumes after publication of the tidal volume trial. Preenrollment Pplat was strongly associated with mortality, and may reflect disease severity independent of tidal volume. Pplat measured early in the course of acute lung injury, after accounting for tidal volume, is a respiratory system-specific value with strong prognostic significance.
引用
收藏
页码:1215 / 1222
页数:8
相关论文
共 39 条
[31]  
WEBB HH, 1974, AM REV RESPIR DIS, V110, P556
[32]   Impact of randomized trial results on acute lung injury ventilator therapy in teaching hospitals [J].
Weinert, CR ;
Gross, CR ;
Marinelli, WA .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2003, 167 (10) :1304-1309
[33]   The physiological challenges of the 1952 Copenhagen poliomyelitis epidemic and a renaissance in clinical respiratory physiology [J].
West, JB .
JOURNAL OF APPLIED PHYSIOLOGY, 2005, 99 (02) :424-432
[34]  
Wheeler AP, 2006, NEW ENGL J MED, V354, P2213
[35]  
Wiedemann HP, 2006, NEW ENGL J MED, V354, P2564
[36]  
Wiedemann HP, 2000, JAMA-J AM MED ASSOC, V283, P1995
[37]  
Wiedemann HP, 2002, CRIT CARE MED, V30, P1
[38]   Ventilation of patients with acute lung injury and acute respiratory distress syndrome: Has new evidence changed clinical practice? [J].
Young, MP ;
Manning, HL ;
Wilson, DL ;
Mette, SA ;
Riker, RR ;
Leiter, JC ;
Liu, SK ;
Bates, JT ;
Parsons, PE .
CRITICAL CARE MEDICINE, 2004, 32 (06) :1260-1265
[39]  
ZAR J, 1985, BIOSTAT ANAL, P145