Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses

被引:142
作者
Hsu, CC
Chao, CK
Wang, JL
Hou, SM
Tsai, YT
Lin, J
机构
[1] Natl Taiwan Univ Hosp, Dept Orthoped Surg, Taipei 100, Taiwan
[2] Natl Taiwan Univ Sci & Technol, Dept Mech Engn, Taipei 106, Taiwan
关键词
pedicle screw; pullout strength; pullout test; finite element analysis;
D O I
10.1016/j.orthres.2004.11.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Screw loosening can threaten pedicle screw fixation of the spine. Conical screws can improve the bending strength, but studies of their pullout strength as compared with that of cylindrical screws have shown wide variation. In the present study, polyurethane foam with two different densities (0.32 and 0.16 gm/cm(3)) was used to compare the pullout strength and stripping torque among three kinds of pedicle screws with different degrees of core tapering. Three-dimensional finite element models were also developed to compare the structural performance of these screws and to predict their pullout strength. In the mechanical tests, pullout strength was consistently higher in the higher density foam and was closely related to screw insertion torque (r = 0.87 and 0.81 for the high and low density foam, respectively) and stripping torque (r = 0.92 and 0.78, respectively). Conical core screws with effective foam compaction had significantly higher pullout strength and insertion torque than cylindrical core screws (p < 0.05). The results of finite element analyses were closely related to those of the mechanical tests in both situations with or without foam compaction. This study led to three conclusions: polyurethane foam bone yielded consistent experimental results; screws with a conical core could significantly increase pullout strength and insertion torque over cylindrical; and finite element models could reliably reflect the results of mechanical tests. (c) 2004 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:788 / 794
页数:7
相关论文
共 20 条
[1]
Abshire B B, 2001, Spine J, V1, P408, DOI 10.1016/S1529-9430(01)00119-X
[2]
ALLEN RF, 1998, ASTM STAND MED DEVIC
[3]
Mechanical properties of adult vertebral cancellous bone: Correlation with collagen intermolecular cross-links [J].
Banse, X ;
Sims, TJ ;
Bailey, AJ .
JOURNAL OF BONE AND MINERAL RESEARCH, 2002, 17 (09) :1621-1628
[4]
Barber JW, 1998, J SPINAL DISORD, V11, P215
[5]
Mechanical performance of standard and cannulated 4.0-mm cancellous bone screws [J].
Brown, GA ;
McCarthy, T ;
Bourgeault, CA ;
Callahan, DJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2000, 18 (02) :307-312
[6]
Moments and forces during pedicle screw insertion -: In vitro and in vivo measurements [J].
Bühler, DW ;
Berlemann, U ;
Oxland, TR ;
Nolte, LP .
SPINE, 1998, 23 (11) :1220-1227
[7]
Choi W, 2002, 48 ANN M ORTH RES SO
[8]
CORRELATIONS BETWEEN SCREW HOLE PREPARATION, TORQUE OF INSERTION, AND PULLOUT STRENGTH FOR SPINAL SCREWS [J].
DAFTARI, TK ;
HORTON, WC ;
HUTTON, WC .
JOURNAL OF SPINAL DISORDERS, 1994, 7 (02) :139-145
[9]
EASTELL R, 1990, J BONE MINER RES, V5, P1237
[10]
Gausepohl T, 2001, INJURY, V32, pD1