The key rationale for a nonmodular flexible press-fit cup was to maximize long-term stability with a cementless, porous metal-coated cup that is low in stiffness (no metal shell) and to achieve fixation solely through biradial eccentricity between the cup and the acetabular cavity. We asked whether the promising results achieved at 5 and 10 years would be maintained at 15 years. We reviewed 261 patients who received the first 280 Morscher Press-Fit (TM) Cups. One hundred twenty patients (126 hips) died. One hundred one patients (112 hips) had a clinical and radiographic followup after a minimum of 13.5 years (mean, 14.7 years; range, 13.5-17.0 years). Twenty-four patients with 26 hips were clinically examined or interviewed by telephone. Three of the 101 patients were lost to followup. We judged the results excellent or good in 96% of the hips. The 15-year overall survivorship was 95.3% and with the end point of aseptic loosening, the survivorship was 97.5%. Wear was greater in cups with an inclination greater than 45 and in metal-polyethylene pairings compared with ceramic-polyethylene pairings. This cup design performs well over the long term.
引用
收藏
页码:114 / 121
页数:8
相关论文
共 48 条
[1]
Nine-year results of Muller cemented titanium Straight Stems in total hip replacement [J].
Acklin, YP ;
Berli, BJ ;
Frick, W ;
Elke, R ;
Morscher, EW .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2001, 121 (07) :391-398
[2]
Berger RA, 1997, CLIN ORTHOP RELAT R, P216
[3]
The cemented MS-30 stem in total hip replacement, matte versus polished surface: Minimum of five years of clinical and radiographic results of a prospective study [J].
Berli, B ;
Elke, R ;
Morscher, EW .
STAINLESS STEELS FOR MEDICAL AND SURGICAL APPLICATIONS, 2003, 1438 :249-261
[4]
BERLI B, 2004, PRESSFITPFANNEN, P175
[5]
Ten-year survival of the MS-30 matt-surfaced cemented stem [J].
Berli, BJ ;
Schäfer, D ;
Morscher, EW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (07) :928-933
[6]
Bono J V, 1994, J Arthroplasty, V9, P119, DOI 10.1016/0883-5403(94)90059-0
[7]
Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
[8]
Clarke H J, 1991, J Arthroplasty, V6, P335, DOI 10.1016/S0883-5403(06)80185-3
[9]
The Harris-Galante porous-coated acetabular component with screw fixation - An average ten-year follow-up study [J].
Clohisy, JC ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01) :66-73
[10]
FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS [J].
DAUBIGNE, RM ;
POSTEL, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (03) :451-475