Nine-year results of Muller cemented titanium Straight Stems in total hip replacement

被引:29
作者
Acklin, YP [1 ]
Berli, BJ [1 ]
Frick, W [1 ]
Elke, R [1 ]
Morscher, EW [1 ]
机构
[1] Univ Basel, Felix Platter Spital, LOB, Dept Orthopaed, CH-4012 Basel, Switzerland
关键词
titanium; straight stem; arthroplasty; Muller; hip replacement;
D O I
10.1007/s004020000254
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
At the Orthopaedic Department of the University of Basel, a total of 540 cemented Muller titanium alloy (Ti6Al7Nb) Straight Stems were inserted between 1989 and 1993. A cohort of 120 consecutive patients (66 women, 54 men) with 126 prostheses operated on between March and December 1989 were followed clinically and radiologically in a prospective manner for a mean observation time of 9.1 years. In all cases, the Muller titanium alloy Straight Stem was combined with the senior author's (E.W.M.) Press-Fit Cup. The mean age of the patients at surgery was 66 (range 43-93) years. Fourty patients (41 hips) died, 9 were interviewed by telephone, none was 'lost to follow-up'. Seventy-one patients with 76 hip replacements were available for the follow-up. Four hips had been revised: two of them due to aseptic loosening of the femoral component, one because of a late infection - all after 9 years - and one owing to a periprosthetic fracture after 6 years. The 9-year overall survivorship is 96.8%, and for aseptic loosening of the stem 98.4%. None of the cups had to be revised for aseptic loosening. The clinical result (according to Merle d'Aubigne) was excellent and good in 88%, moderate in 8%, and poor in 4%. The radiological analysis showed no osteolysis or radiolucent lines in 59 prostheses (78%). Nine stems (12%) showed a radiolucent line. Focal osteolysis was detected in 8 cases (10%) in one or more Gruen zones. The distribution of the osteolyses shows that predominantly zones VII, VI, V, and II are affected in decreasing frequency. No osteolysis was detected on the acetabular side. Our results do not confirm the high rate of osteolysis and revisions with the Muller titanium alloy Straight Stem presented by some other institutions. The verdict on a specific endoprosthetic implant must be made by combined assessment of the design, the implant surface condition, the material, the cement, the cementing procedure and the operative technique. The statement made in earlier publications that cemented titanium alloy should not be used as a femoral stem prosthesis should be reconsidered.
引用
收藏
页码:391 / 398
页数:8
相关论文
共 38 条
[1]
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]
WEAR INDUCED BY MOTION BETWEEN BONE AND TITANIUM OR COBALT-CHROME ALLOYS [J].
BISCHOFF, UW ;
FREEMAN, MAR ;
SMITH, D ;
TUKE, MA ;
GREGSON, PJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (05) :713-716
[3]
Bragdon C R, 1996, Proc Inst Mech Eng H, V210, P157, DOI 10.1243/PIME_PROC_1996_210_408_02
[4]
Buly R L, 1992, J Arthroplasty, V7, P315, DOI 10.1016/0883-5403(92)90056-V
[5]
CATTANEO FM, 1995, THESIS U BERNE
[6]
FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS [J].
DAUBIGNE, RM ;
POSTEL, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (03) :451-475
[7]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[8]
Eingartner C, 1997, Swiss Surg, V3, P49
[9]
Ten-year results of a cemented mild grit blasted titanium-aluminium-vanadium stem in total-hip-arthiroplasly. [J].
Hinrichs, F ;
Boudriot, U ;
Griss, P .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2000, 138 (01) :52-56
[10]
Loosening of matt and polished cemented femoral stems [J].
Howie, DW ;
Middleton, RG ;
Costi, K .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (04) :573-576