An electronic tongue using potentiometric all-solid-state PVC-membrane sensors for the simultaneous quantification of ammonium and potassium ions in water

被引:79
作者
Gallardo, J
Alegret, S
Muñoz, R
De-Román, M
Leija, L
Hernández, PR
del Valle, M
机构
[1] Autonomous Univ Barcelona, Dept Chem, Sensors & Biosensors Grp, Bellaterra 08193, Catalonia, Spain
[2] CINVESTAV, Dept Elect Engn, Bioelect Sect, Mexico City 14000, DF, Mexico
关键词
sensor array; PVC membrane; ion-selective electrode; artificial neural networks; ammonium; potassium;
D O I
10.1007/s00216-003-2042-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The simultaneous determination of NH4+ and K+ in solution has been attempted using a potentiometric sensor array and multivariate calibration. The sensors used are rather non-specific and of all-solid-state type, employing polymeric (PVC) membranes. The subsequent data processing is based on the use of a multilayer artificial neural network (ANN). This approach is given the name 'electronic tongue' because it mimics the sense of taste in animals. The sensors incorporate, as recognition elements, neutral carriers belonging to the family of the ionophoric antibiotics. In this work the ANN type is optimized by studying its topology, the training algorithm, and the transfer functions. Also, different pretreatments of the starting data are evaluated. The chosen ANN is formed by 8 input neurons, 20 neurons in the hidden layer and 2 neurons in the output layer. The transfer function selected for the hidden layer was sigmoidal and linear for the output layer. It is also recommended to scale the starting data before training. A correct fit for the test data set is obtained when it is trained with the Bayesian regularization algorithm. The viability for the determination of ammonium and potassium ions in synthetic samples was evaluated; cumulative prediction errors of approximately 1% (relative values) were obtained. These results were comparable with those obtained with a generalized regression ANN as a reference algorithm. In a final application, results close to the expected values were obtained for the two considered ions, with concentrations between 0 and 40 mmol L-1.
引用
收藏
页码:248 / 256
页数:9
相关论文
共 35 条
  • [1] RESPONSE CHARACTERISTICS OF CONDUCTIVE POLYMER COMPOSITE SUBSTRATE ALL-SOLID-STATE POLY(VINYL CHLORIDE) MATRIX MEMBRANE ION-SELECTIVE ELECTRODES IN AERATED AND NITROGEN-SATURATED SOLUTIONS
    ALEGRET, S
    FLORIDO, A
    [J]. ANALYST, 1991, 116 (05) : 473 - 476
  • [2] BIOSENSORS BASED ON CONDUCTING FILLED POLYMER ALL-SOLID-STATE PVC MATRIX MEMBRANE ELECTRODES
    ALEGRET, S
    MARTINEZFABREGAS, E
    [J]. BIOSENSORS, 1989, 4 (05) : 287 - 297
  • [3] Alegret S., 2003, INTEGRATED ANAL SYST
  • [4] Application of neural network calibrations to an halide ISE array
    Baret, M
    Massart, DL
    Fabry, P
    Conesa, F
    Eichner, C
    Menardo, C
    [J]. TALANTA, 2000, 51 (05) : 863 - 877
  • [5] SPARINGLY SELECTIVE ION-SELECTIVE ELECTRODE ARRAYS FOR MULTICOMPONENT ANALYSIS
    BEEBE, K
    UERZ, D
    SANDIFER, J
    KOWALSKI, B
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (01) : 66 - 71
  • [6] NONLINEAR CALIBRATION USING PROJECTION PURSUIT REGRESSION - APPLICATION TO AN ARRAY OF ION-SELECTIVE ELECTRODES
    BEEBE, KR
    KOWALSKI, BR
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (20) : 2273 - 2278
  • [7] PROCESSING OF SIGNALS FROM AN ION-SELECTIVE ELECTRODE ARRAY BY A NEURAL NETWORK
    BOS, M
    BOS, A
    VANDERLINDEN, WE
    [J]. ANALYTICA CHIMICA ACTA, 1990, 233 (01) : 31 - 39
  • [8] DATA-PROCESSING BY NEURAL NETWORKS IN QUANTITATIVE CHEMICAL-ANALYSIS
    BOS, M
    BOS, A
    VANDERLINDEN, WE
    [J]. ANALYST, 1993, 118 (04) : 323 - 328
  • [9] Simultaneous determination of potassium and sodium by optode spectra and an artificial neural network algorithm