Adaptive approach to accurate analysis of small-diameter vessels in cineangiograms

被引:42
作者
Sonka, M
Reddy, GK
Winniford, MD
Collins, SM
机构
[1] CEMAX ICON INC, FREMONT, CA 94539 USA
[2] UNIV IOWA, DEPT INTERNAL MED, IOWA CITY, IA 52242 USA
[3] UNIV IOWA, DEPT RADIOL, IOWA CITY, IA 52242 USA
关键词
coronary artery disease; coronary border detection; quantitative coronary angiography; small-diameter vessels;
D O I
10.1109/42.552058
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In coronary vessels smaller than 1 mm in diameter, it is difficult to accurately identify lumen borders using existing border detection techniques, Computer-detected diameters of small coronary vessels are often severely overestimated due to the influence of the imaging system point spread function and Computer-detected the use of an edge operator designed for a broad range of diameter vessel sizes, Computer-detected diameters may be corrected if a calibration curve for the X-ray system is available, Unfortunately, the performance of this postprocessing diameter correction approach is severely limited by the presence of image noise, We report here a new approach that uses a two-stage adaption of edge operator parameters to optimally match the edge operator to the local lumen diameter, In the first stage, approximate lumen diameters are detected using a single edge operator in a half-resolution image. Depending on the approximate lumen size, one of three edge operators is selected for the second full-resolution stage in which left and right coronary borders are simultaneously identified. The method was tested in a set of 72 segments of nine angiographic phantom vessels with diameters ranging from 0.46 to 4.14 mm and in 82 clinical coronary angiograms, Performance of the adaptive simultaneous border detection method was compared to that of a conventional border detection method and to that of a postprocessing diameter correction border detection method, Adaptive border detection yielded significantly improved accuracy in small phantom vessels and across all vessel sizes in comparison to the conventional and postprocessing diameter correction methods (p < 0.001 in all cases), Adaptive simultaneous coronary border detection provides both accurate and robust quantitative analysis of coronary vessels of all sizes.
引用
收藏
页码:87 / 95
页数:9
相关论文
共 36 条
[1]   EVALUATION OF A PERSONAL COMPUTER-BASED QUANTITATIVE CORONARY ANALYSIS SYSTEM FOR RAPID ASSESSMENT OF CORONARY STENOSES [J].
ALVAREZ, LG ;
JACKSON, SA ;
BERRY, JA ;
EICHHORN, EJ .
AMERICAN HEART JOURNAL, 1992, 123 (06) :1500-1510
[2]  
[Anonymous], COMPUTER APPL ANGIOG
[3]   ACCURACY OF INDIVIDUAL AND PANEL VISUAL INTERPRETATIONS OF CORONARY ARTERIOGRAMS - IMPLICATIONS FOR CLINICAL DECISIONS [J].
BEAUMAN, GJ ;
VOGEL, RA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (01) :108-113
[4]   QUANTITATIVE CORONARY ARTERIOGRAPHY - ESTIMATION OF DIMENSIONS, HEMODYNAMIC RESISTANCE, AND ATHEROMA MASS OF CORONARY-ARTERY LESIONS USING ARTERIOGRAM AND DIGITAL COMPUTATION [J].
BROWN, BG ;
BOLSON, E ;
FRIMER, M ;
DODGE, HT .
CIRCULATION, 1977, 55 (02) :329-337
[5]  
Buchi M, 1990, Int J Card Imaging, V5, P93, DOI 10.1007/BF01833978
[6]  
Collins SM, 1986, CARDIAC IMAGING IMAG
[7]   VARIABILITY IN ANALYSIS OF CORONARY ARTERIOGRAMS [J].
DEROUEN, TA ;
MURRAY, JA ;
OWEN, W .
CIRCULATION, 1977, 55 (02) :324-328
[8]   IN-VIVO COMPARISON OF DIFFERENT QUANTITATIVE EDGE-DETECTION SYSTEMS USED FOR MEASURING CORONARY ARTERIAL DIAMETERS [J].
DESMET, W ;
DESCHEERDER, I ;
BEATT, K ;
HUEHNS, T ;
PIESSENS, J .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1995, 34 (01) :72-80
[9]   OBSERVER AGREEMENT IN EVALUATING CORONARY ANGIOGRAMS [J].
DETRE, KM ;
WRIGHT, E ;
MURPHY, ML ;
TAKARO, T .
CIRCULATION, 1975, 52 (06) :979-986
[10]   A METHOD FOR A FULLY-AUTOMATIC DEFINITION OF CORONARY ARTERIAL EDGES FROM CINEANGIOGRAMS [J].
EICHEL, PH ;
DELP, EJ ;
KORAL, K ;
BUDA, AJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) :313-320