A procedure for the determination of trace amount of cadmium after adsorption of its 1-nitroso-2-naphthol-3,6-disulfonic acid chelate on Ambersorb 572 has been proposed. This chelate is adsorbed on the adsorbent in the pH range 3-8 from large volumes of aqueous solution of water samples with a preconcentration factor of 200. After being sorbed, cadmium was eluted by 5 mL of 2.0 mol L-1 nitric acid solution and determined directly by flame atomic absorption spectrophotometery (FAAS). The detection limit (3 sigma) of cadmium was 0.32 mu g L-1. The precision of the proposed procedure, calculated as the relative standard deviation of recovery in sample solution (100 mL) containing 5 mu g of cadmium was satisfactory (1.9%). The adsorption of cadmium onto adsorbent can formally be described by a Langmuir equation with a maximum adsorption capacity of 19.6 mg g(-1) and a binding constant of 6.5 x 10(-3) L mg(-1). Various parameters, such as the effect of pH and the interference of a number of metal ions on the determination of cadmium, have been studied in detail to optimize the conditions for the preconcentration and determination of cadmium in water samples. This procedure was applied to the determination of cadmium in tap and river water samples.
引用
收藏
页码:77 / 85
页数:9
相关论文
共 31 条
[1]  
Adamson A. W., 1990, Physical Chemistry of Surfaces
[2]  
[Anonymous], CHEM MODIFIED SURFAC
[3]   Determination of Cu, Zn and Cd in water by FAAS after preconcentration by baker's yeast (Saccharomyces cerevisiae) immobilized on sepiolite [J].
Bag, H ;
Lale, M ;
Türker, AR .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (03) :224-230
[4]   On-line preconcentration/determination of cadmium in drinking water on activated carbon using 8-hydroxyquinoline in a flow injection system coupled to an inductively coupled plasma optical emission spectrometer [J].
Cerutti, S ;
Silva, MF ;
Gásquez, JA ;
Olsina, RA ;
Martinez, LD .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (01) :43-50
[5]   Determination of cadmium in mussels by flame atomic absorption spectrometry with preconcentration on a chelating resin in a flow injection system [J].
Enríquez-Domínguez, MF ;
Yebra-Biurrun, MC ;
Bermejo-Barrera, MP .
ANALYST, 1998, 123 (01) :105-108
[6]  
*FAO WHO JOINT EXP, 1997, 50532 FAO WHO JOINT
[7]  
Friberg L, 1986, HDB TOXICOLOGY METAL, V2
[8]   1,8-dihydroxyanthraquinone anchored on silica gel: synthesis and application as solid phase extractant for lead(II), zinc(II) and cadmium(II) prior to their determination by flame atomic absorption spectrometry [J].
Goswami, A ;
Singh, AK .
TALANTA, 2002, 58 (04) :669-678
[9]   Determination of traces of cadmium in natural water samples by flow injection on-line preconcentration-graphite furnace atomic absorption spectrometry [J].
Hirano, Y ;
Nakajima, J ;
Oguma, K ;
Terui, Y .
ANALYTICAL SCIENCES, 2001, 17 (09) :1073-1077
[10]   Vesicular hydride generation - In situ preconcentration - Electrothermal atomic absorption spectrometry determination of sub-parts-per-billion levels of cadmium [J].
Infante, HG ;
Sanchez, MLF ;
SanzMedel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (11) :1333-1336