Determination of traces of cadmium in natural water samples by flow injection on-line preconcentration-graphite furnace atomic absorption spectrometry

被引:18
作者
Hirano, Y
Nakajima, J
Oguma, K
Terui, Y
机构
[1] Chiba Univ, Fac Engn, Dept Mat Technol, Inage Ku, Chiba 2638522, Japan
[2] Hitachi Ltd, Instruments Grp, Analyt Syst Ctr, Design Dept, Katsuta, Ibaraki 3128504, Japan
关键词
D O I
10.2116/analsci.17.1073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection on-line preconcentration-graphite furnace atomic absorption spectrometric method was developed for the determination of traces of cadmium in natural water samples. Cadmium in samples was adsorbed on an iminodiacetate-type chelating resin, Muromac A-1 microcolumn (3 mm i.d. and 10 mm long), and then eluted with 2 mol l(-1) HNO3. The eluate was introduced into the injection tip of an autosampler. The eluate zone with the highest analyte concentration was injected into the graphite furnace by cooperation of a peristaltic pump and a syringe pump of the autosampler, which were controlled by a programmable controller. The present system was successfully applied to the determination of cadmium in natural water samples. A detection limit of 0.2 ng l(-1) was obtained with 12 ml sample loading. The recoveries were 99 and 108% for tap water (4 ml loading) and underground water (12 ml loading), respectively. Analytical results obtained for a river water reference material (JAC-0031, Japan Society for Analytical Chemistry) were close to the reference value.
引用
收藏
页码:1073 / 1077
页数:5
相关论文
共 36 条
[1]   Co-precipitative pre-concentration with sodium diethyldithiocarbamate and ICP-AES determination of Se, Cu, Pb, Zn, Fe, Co, Ni, Mn, Cr and Cd in water [J].
Atanassova, D ;
Stefanova, V ;
Russeva, E .
TALANTA, 1998, 47 (05) :1237-1243
[2]  
Benkhedda I, 1999, J ANAL ATOM SPECTROM, V14, P957
[3]   On-line sample pre-treatment systems interfaced to electrothermal atomic absorption spectrometry [J].
Burguera, JL ;
Burguera, M .
ANALYST, 1998, 123 (04) :561-569
[4]   Direct determination of cadmium and copper in seawater using a transversely heated graphite furnace atomic absorption spectrometer with Zeeman-effect background corrector [J].
Chan, MS ;
Huang, SD .
TALANTA, 2000, 51 (02) :373-380
[5]   Determination of ultra-trace amounts of cadmium, cobalt and nickel in sea-water by electrothermal atomic absorption spectrometry with on-line preconcentration [J].
Chang, HJ ;
Sung, YH ;
Huang, SD .
ANALYST, 1999, 124 (11) :1695-1699
[6]  
CHENG CJ, 1985, B CHEM SOC JPN, V58, P3229
[7]   SIMULTANEOUS MULTIELEMENT ANALYSIS FOR TRACE-METALS IN SEA-WATER BY INDUCTIVELY-COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY AFTER BATCH PRECONCENTRATION ON A CHELATING RESIN [J].
CHENG, CJ ;
AKAGI, T ;
HARAGUCHI, H .
ANALYTICA CHIMICA ACTA, 1987, 198 :173-181
[8]   Determination of cadmium in seawater using automated on-line preconcentration and direct injection graphite furnace atomic absorption spectrometry [J].
Colbert, D ;
Johnson, KS ;
Coale, KH .
ANALYTICA CHIMICA ACTA, 1998, 377 (2-3) :255-262
[9]   Simultaneous determination of trace amounts of cadmium, nickel and cobalt in water samples by adsorptive voltammetry using ammonium 2-amino-cyclopentene dithiocarboxylate as a chelating agent [J].
Ensafi, AA ;
Zarei, K .
TALANTA, 2000, 52 (03) :435-440
[10]   FLOW-INJECTION ONLINE SORBENT EXTRACTION PRECONCENTRATION FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, Z ;
SPERLING, M ;
WELZ, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (07) :639-646