Flowcytometric analysis of basophil counts in human blood and inaccuracy of hematology analyzers

被引:49
作者
Ducrest, S [1 ]
Meier, F [1 ]
Tschopp, C [1 ]
Pavlovic, R [1 ]
Dahinden, CA [1 ]
机构
[1] Univ Hosp Bern, Inselspital, Inst Immunol, CH-3010 Bern, Switzerland
关键词
basophils; chemokines; facs analysis; immunoglobulin E; in vitro tests;
D O I
10.1111/j.1398-9995.2005.00910.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: Differential leukocyte counts are of proven clinical value, but information about basophil counts in normal and disease conditions is scarce although basophils are regarded as key effector cells in allergy. Aims: To establish and validate flowcytometric methods for counting basophils in peripheral human blood, to determine reference values, and to examine the accuracy of two widely used hematology analyzers. Methods: Basophils were measured in whole blood by flowcytometry after staining with antibodies against the IL-3-receptor (CD123) or the eotaxin-receptor (CCR3) combined with other markers used for gating or validation purposes. Results: The basophil percentages in 95 healthy adults showed an excellent correlation between the two independent flowcytometric methods, demonstrating that both are accurate and precise. The most robust maker is CCR3, which seems to be sufficient to specifically identify basophils. Normal values of relative and absolute blood basophils counts were 0.22-1.28% and 0.014-0.087 G/L (95% reference intervals), respectively. Basophil counts measured with two hematology analyzers Coulter GEN-S and ADVIA-120 showed no correlation between these instruments. Comparing the data obtained by flowcytometry and the analyzers demonstrate that basophil counts of the GEN-S are erratic, while the ADVIA-120 gives at least an estimation of true basophil numbers. Conclusions: We provide a solid description and validation of a novel and rapid method for the flowcytometric enumeration of basophil in whole blood. The fact that the most heavily used Hematology autoanalyzer gives completely erroneous results could explain why basophils counts have not yet received recognition as a clinically useful diagnostic marker.
引用
收藏
页码:1446 / 1450
页数:5
相关论文
共 20 条
[1]  
BALDWA VS, 1975, ANN ALLERGY, V34, P351
[2]  
Calbi M, 1996, J INVEST ALLERG CLIN, V6, P383
[3]   CD123bright plasmacytoid predendritic cells:: Progenitors undergoing cell fate conversion? [J].
Comeau, MR ;
de Vries, ARV ;
Maliszewski, CR ;
Galibert, L .
JOURNAL OF IMMUNOLOGY, 2002, 169 (01) :75-83
[4]  
Falcone FH, 2000, BLOOD, V96, P4028
[5]   COMPARISON BETWEEN NUMBER OF BASOPHILS, BLOOD HISTAMINE, AND HISTAMINE-RELEASE IN CANCER AND NONCANCER PATIENTS [J].
GALOPPIN, L ;
NOIROT, C ;
WASTIAUX, JP ;
SCHEINMANN, P ;
PAUPE, J ;
BURTIN, C .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1989, 84 (04) :501-506
[6]   Flow cytometric analysis of basophil numbers in chronic urticaria: basopenia is related to serum histamine releasing activity [J].
Grattan, CEH ;
Walpole, D ;
Francis, DM ;
Niimi, N ;
Dootson, G ;
Edler, S ;
Corbett, MF ;
Barr, RM .
CLINICAL AND EXPERIMENTAL ALLERGY, 1997, 27 (12) :1417-1424
[7]   Blood basophil numbers in chronic ordinary urticaria and healthy controls: diurnal variation, influence of loratadine and prednisolone and relationship to disease activity [J].
Grattan, CEH ;
Dawn, G ;
Gibbs, S ;
Francis, DM .
CLINICAL AND EXPERIMENTAL ALLERGY, 2003, 33 (03) :337-341
[8]   Pseudobasophilia as an erroneous white blood cell differential count with a discrepancy between automated cell counters: report of two cases [J].
Hur, M ;
Lee, YK ;
Lee, KM ;
Kim, HJ ;
Cho, HI .
CLINICAL AND LABORATORY HAEMATOLOGY, 2004, 26 (04) :287-290
[9]  
Koenn M E, 2001, Clin Lab Sci, V14, P238
[10]   INTERLEUKIN-3-DEPENDENT MEDIATOR RELEASE IN BASOPHILS TRIGGERED BY C5A [J].
KURIMOTO, Y ;
DEWECK, AL ;
DAHINDEN, CA .
JOURNAL OF EXPERIMENTAL MEDICINE, 1989, 170 (02) :467-479