End-column amperometric detection in capillary electrophoresis: Influence of separation-related parameters on the observed half-wave potential for dopamine and catechol

被引:125
作者
Wallenborg, SR
Nyholm, L
Lunte, CE [1 ]
机构
[1] Univ Kansas, Dept Chem, Lawrence, KS 66045 USA
[2] Univ Uppsala, Dept Analyt Chem, S-75121 Uppsala, Sweden
关键词
D O I
10.1021/ac980737v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capillary electrophoresis (CE) was coupled to a microelectrode-based end-column amperometric detector. The influences of separation voltage, CE buffer concentration, and capillary-to-electrode distance on the observed hydrodynamic voltammetry of dopamine and catechol were studied using a separation capillary with an i.d. of 25 mu m. It was found that an increased CE voltage, increased buffer concentration, or decreased capillary-to-electrode distance resulted in a positive shift of the observed halfwave potentials for both dopamine and catechol, At a constant separation current of 1.6 mu A, the observed halfwave potential was found to increase with applied separation voltage. Furthermore, when experiments were carried out with a platinum quasi-reference electrode instead of a Ag/AgCl reference electrode, similar shifts in half-wave potential were observed, These results indicate that the observed shifts are an effect of the separation voltage rather than the separation current or a change in the reference potential. The characteristics of end-column detection with and without a fracture decoupler were compared. It was found that the effects of separation voltage, CE buffer concentration, and capillary-to-electrode distance were minimized by the use of a decoupling device. The observed half-wave potentials for dopamine and catechol were more positive when a CE capillary without a decoupler was employed compared to when a decoupler was used. Additionally, using the fracture decoupler, the observed half-wave potentials for both dopamine and catechol were approximately the same as when no CE voltage was applied (i.e., when the hydrodynamic voltammograms were recorded under now injection conditions).
引用
收藏
页码:544 / 549
页数:6
相关论文
共 31 条
[1]   CAPILLARY ELECTROPHORESIS WITH AMPEROMETRIC DETECTION USING A POROUS CELLULOSE-ACETATE JOINT [J].
CHEN, IC ;
WHANG, CW .
JOURNAL OF CHROMATOGRAPHY, 1993, 644 (01) :208-212
[2]   AN ELECTROCHEMICAL COIL FOR END-COLUMN AMPEROMETRIC DETECTION IN CAPILLARY ELECTROPHORESIS [J].
CHEN, MC ;
HUANG, HJ .
ANALYTICAL CHEMISTRY, 1995, 67 (21) :4010-4014
[3]   Rudimentary capillary-electrode alignment for capillary electrophoresis with electrochemical detection [J].
Fermier, AM ;
Gostkowski, ML ;
Colon, LA .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1661-1664
[4]   Square-wave voltammetry detection for capillary electrophoresis [J].
Gerhardt, GC ;
Cassidy, RM ;
Baranski, AS .
ANALYTICAL CHEMISTRY, 1998, 70 (10) :2167-2173
[5]   Optimization of the separation and detection of the enantiomers of isoproterenol in microdialysis samples by cyclodextrin-modified capillary electrophoresis using electrochemical detection [J].
Hadwiger, ME ;
Torchia, SR ;
Park, S ;
Biggin, ME ;
Lunte, CE .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 681 (02) :241-249
[6]  
Holland LA, 1998, ANAL COMMUN, V35, p1H
[7]   DETERMINATION OF THIOLS BY CAPILLARY ELECTROPHORESIS WITH ELECTROCHEMICAL DETECTION USING A PALLADIUM FIELD-DECOUPLER AND CHEMICALLY-MODIFIED ELECTRODES [J].
HUANG, XJ ;
KOK, WT .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :347-353
[8]  
KAGANOV M, 1992, AM LAB, P59
[9]   SOLID-STATE FIELD DECOUPLER FOR OFF-COLUMN DETECTION IN CAPILLARY ELECTROPHORESIS [J].
KOK, WT ;
SAHIN, Y .
ANALYTICAL CHEMISTRY, 1993, 65 (18) :2497-2501
[10]   High temporal resolution monitoring of glutamate and aspartate in vivo using microdialysis on-line with capillary electrophoresis with laser-induced fluorescence detection [J].
Lada, MW ;
Vickroy, TW ;
Kennedy, RT .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4560-4565