End-column amperometric detection in capillary electrophoresis: Influence of separation-related parameters on the observed half-wave potential for dopamine and catechol

被引:126
作者
Wallenborg, SR
Nyholm, L
Lunte, CE [1 ]
机构
[1] Univ Kansas, Dept Chem, Lawrence, KS 66045 USA
[2] Univ Uppsala, Dept Analyt Chem, S-75121 Uppsala, Sweden
关键词
D O I
10.1021/ac980737v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capillary electrophoresis (CE) was coupled to a microelectrode-based end-column amperometric detector. The influences of separation voltage, CE buffer concentration, and capillary-to-electrode distance on the observed hydrodynamic voltammetry of dopamine and catechol were studied using a separation capillary with an i.d. of 25 mu m. It was found that an increased CE voltage, increased buffer concentration, or decreased capillary-to-electrode distance resulted in a positive shift of the observed halfwave potentials for both dopamine and catechol, At a constant separation current of 1.6 mu A, the observed halfwave potential was found to increase with applied separation voltage. Furthermore, when experiments were carried out with a platinum quasi-reference electrode instead of a Ag/AgCl reference electrode, similar shifts in half-wave potential were observed, These results indicate that the observed shifts are an effect of the separation voltage rather than the separation current or a change in the reference potential. The characteristics of end-column detection with and without a fracture decoupler were compared. It was found that the effects of separation voltage, CE buffer concentration, and capillary-to-electrode distance were minimized by the use of a decoupling device. The observed half-wave potentials for dopamine and catechol were more positive when a CE capillary without a decoupler was employed compared to when a decoupler was used. Additionally, using the fracture decoupler, the observed half-wave potentials for both dopamine and catechol were approximately the same as when no CE voltage was applied (i.e., when the hydrodynamic voltammograms were recorded under now injection conditions).
引用
收藏
页码:544 / 549
页数:6
相关论文
共 31 条
[11]   DUAL ELECTROCHEMICAL DETECTION OF CYSTEINE AND CYSTINE IN CAPILLARY ZONE ELECTROPHORESIS [J].
LIN, BL ;
COLON, LA ;
ZARE, RN .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :263-270
[12]   USE OF AN ON-COLUMN FRACTURE IN CAPILLARY ZONE ELECTROPHORESIS FOR SAMPLE INTRODUCTION [J].
LINHARES, MC ;
KISSINGER, PT .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2076-2078
[13]   END-COLUMN ELECTROCHEMICAL DETECTION FOR INORGANIC AND ORGANIC-SPECIES IN HIGH-VOLTAGE CAPILLARY ELECTROPHORESIS [J].
LU, WZ ;
CASSIDY, RM ;
BARANSKI, AS .
JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2) :433-440
[14]   BACKGROUND-NOISE IN CAPILLARY ELECTROPHORETIC AMPEROMETRIC DETECTION [J].
LU, WZ ;
CASSIDY, RM .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :200-204
[15]   Improved end-column amperometric detection for capillary electrophoresis [J].
Matysik, FM .
JOURNAL OF CHROMATOGRAPHY A, 1996, 742 (1-2) :229-234
[16]   Non-aqueous capillary electrophoresis with electrochemical detection [J].
Matysik, FM .
JOURNAL OF CHROMATOGRAPHY A, 1998, 802 (02) :349-354
[17]   CAPILLARY ELECTROPHORESIS WITH ELECTROCHEMICAL DETECTION EMPLOYING AN ON-COLUMN NAFION JOINT [J].
OSHEA, TJ ;
GREENHAGEN, RD ;
LUNTE, SM ;
LUNTE, CE ;
SMYTH, MR ;
RADZIK, DM ;
WATANABE, N .
JOURNAL OF CHROMATOGRAPHY, 1992, 593 (1-2) :305-312
[18]   DETECTION OF CARBOHYDRATES BY CAPILLARY ELECTROPHORESIS WITH PULSED AMPEROMETRIC DETECTION [J].
OSHEA, TJ ;
LUNTE, SM ;
LACOURSE, WR .
ANALYTICAL CHEMISTRY, 1993, 65 (07) :948-951
[19]   CAPILLARY ELECTROPHORESIS ELECTROCHEMISTRY OF MICRODIALYSIS SAMPLES FOR PHARMACOKINETIC STUDIES [J].
OSHEA, TJ ;
TELTINGDIAZ, MW ;
LUNTE, SM ;
LUNTE, CE ;
SMYTH, MR .
ELECTROANALYSIS, 1992, 4 (04) :463-468
[20]   A PERFLUOROSULFONATED IONOMER END-COLUMN ELECTRICAL DECOUPLER FOR CAPILLARY ELECTROPHORESIS/ELECTROCHEMICAL DETECTION [J].
PARK, S ;
LUNTE, CE .
ANALYTICAL CHEMISTRY, 1995, 67 (23) :4366-4370