A validated computational fluid dynamics model to estimate hemolysis in a rotary blood pump

被引:84
作者
Arvand, A [1 ]
Hormes, M [1 ]
Reul, H [1 ]
机构
[1] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, D-52074 Aachen, Germany
关键词
rotary blood pump; computational fluid dynamics; in vitro hemolysis tests; hemolysis model;
D O I
10.1111/j.1525-1594.2005.29089.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A major part of developing rotary blood pumps requires the optimization of hemolytic properties of the entire pump. Application of a suited computational fluid dynamics (CFD)-based hemolysis model allows approximation of blood damage in an early phase of the design process. Thus, a drastic reduction of time- and cost- intensive hemolysis experiments can be achieved. For the MicroDiagonal Pump (MDP), still under development at Helmholtz-Institute in Aachen, Germany, different pump configurations have been analyzed, both numerically and experimentally. The CFD model of the pump has been successfully validated based on the comparison of the pressure head curves (H-Q curves), as discussed in a prior publication. In the present study, the authors focus on the development of a semiempiric blood damage model using the CFD and in vitro hemolysis data. On the one hand, mean key characteristics (shear stress and exposure time) and other characteristics affecting blood damage have been calculated based on numerical data. On the other hand, in vitro hemolysis tests have been accomplished in order to determine the hemolytic curves of two different pump configurations (with the same impeller but different tip clearances). Finally, a new function based on a general power law has been defined by means of the mean key characteristics. The unknown constants of the function have been determined by multidimensional regression analysis using the hemolytic curves. For the final validation of this new blood damage model, the calculated and the in vitro obtained hemolysis indices at the specific VAD operating point have been compared for all pump configurations. The comparison showed an excellent agreement, both qualitatively and quantitatively.
引用
收藏
页码:531 / 540
页数:10
相关论文
共 26 条
[1]  
AKDIS M, 2002, INT J ARTIF ORGANS, V7, P666
[2]   Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics [J].
Apel, J ;
Paul, R ;
Klaus, S ;
Siess, T ;
Reul, H .
ARTIFICIAL ORGANS, 2001, 25 (05) :341-347
[3]  
APEL J, 2002, THESIS RWTH AACHEN
[4]   Comparison of hydraulic and hemolytic properties of different impeller designs of an implantable rotary blood pump by computational fluid dynamics [J].
Arvand, A ;
Hahn, N ;
Hormes, M ;
Akdis, M ;
Martin, M ;
Reul, H .
ARTIFICIAL ORGANS, 2004, 28 (10) :892-898
[5]  
ARVAND A, 2003, ARTIF ORGANS, V27, P367
[6]  
ARVAND A, 2002, ISRBP C OS JAP
[7]  
ARVAND A, 2002, INT J ARTIF ORGANS, V7, P695
[8]   3-DIMENSIONAL NUMERICAL PREDICTION OF STRESS LOADING OF BLOOD PARTICLES IN A CENTRIFUGAL PUMP [J].
BLUDSZUWEIT, C .
ARTIFICIAL ORGANS, 1995, 19 (07) :590-596
[9]  
Bludszuweit C., 1994, THESIS U STRATHCLYDE
[10]   Experimental testing of a new left ventricular assist device - The microdiagona blood pump [J].
Christiansen, S ;
Demircan, L ;
Kwant, PB ;
Akdis, M ;
Rex, S ;
Buhre, W ;
Langebartels, G ;
Kuruc, N ;
Nikolin, S ;
Reul, H ;
Autschbach, R .
ASAIO JOURNAL, 2004, 50 (03) :200-204