A study on optimum insulation thickness in walls and energy savings in Tunisian buildings based on analytical calculation of cooling and heating transmission loads

被引:197
作者
Daouas, Naouel [1 ]
机构
[1] Ecole Natl Ingenieurs Monastir, Dept Genie Energet, Monastir 5019, Tunisia
关键词
Optimum insulation thickness; Energy savings; Cooling loads; Heating loads; Complex Finite Fourier Transform; Life-cycle cost; PERIODIC-SOLUTION; EXTERNAL WALLS; MULTILAYER WALLS; FLAT ROOFS; TURKEY; CONDUCTION; RESPECT; ZONE; FLOW; HOT;
D O I
10.1016/j.apenergy.2010.07.030
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
080707 [能源环境工程]; 082001 [油气井工程];
摘要
In Tunisian climate, both heating in winter and cooling in summer are required to reach comfort levels. Due to the significant increase in building energy consumption, insulation of external walls is recently applied with a thickness typically ranging between 4 cm and 5 cm regardless of structure and orientation of walls and of economic parameters. In the present study, optimum insulation thickness, energy saving and payback period are calculated for a typical wall structure based on both cooling and heating loads. Yearly transmission loads are rigorously estimated using an analytical method based on Complex Finite Fourier Transform (CFFT). Considering different wall orientations, the west and east facing walls are the least favourite in the cooling season, whereas the north-facing wall is the least favourite in the heating season. A life-cycle cost analysis over a building lifetime of 30 years shows that the south orientation is the most economical with an optimum insulation thickness of 10.1 cm, 71.33% of energy savings and a payback period of 3.29 years. It is noted that wall orientation has a small effect on optimum insulation thickness, but a more significant effect on energy savings which reach a maximum value of 23.78 TND/m(2) in the case of east facing wall. A sensitivity analysis shows that economic parameters, such as insulation cost, energy cost, inflation and discount rates and building lifetime, have a noticeable effect on optimum insulation and energy savings. Comparison of the present study with the degree-days model is also performed. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:156 / 164
页数:9
相关论文
共 23 条
[1]
Al-Sanea S A., 2011, International Journal of Ambient Energy, V23, DOI DOI 10.1080/01430750.2002.9674880
[2]
Effect of electricity tariff on the optimum insulation-thickness in building walls as determined by a dynamic heat-transfer model [J].
Al-Sanea, SA ;
Zedan, MF ;
Al-Ajlan, SA .
APPLIED ENERGY, 2005, 82 (04) :313-330
[3]
*ASHRAE INC, 1997, HDB FUNDAMENTALS
[4]
Determination of optimum insulation thickness for building walls with respect to various fuels and climate zones in Turkey [J].
Bolatturk, A .
APPLIED THERMAL ENGINEERING, 2006, 26 (11-12) :1301-1309
[5]
Optimum insulation thicknesses for building walls with respect to cooling and heating degree-hours in the warmest zone of Turkey [J].
Bolatturk, Ali .
BUILDING AND ENVIRONMENT, 2008, 43 (06) :1055-1064
[6]
Optimum insulation thickness of external walls for energy saving [J].
Çomakli, K ;
Yüksel, B .
APPLIED THERMAL ENGINEERING, 2003, 23 (04) :473-479
[7]
Analytical periodic solution for the study of thermal performance and optimum insulation thickness of building walls in Tunisia [J].
Daouas, Naouel ;
Hassen, Zaineb ;
Aissia, Habib Ben .
APPLIED THERMAL ENGINEERING, 2010, 30 (04) :319-326
[8]
Optimization of insulation thickness for external walls using different energy-sources [J].
Dombayci, O. Altan ;
Golcu, Mustafa ;
Pancar, Yasar .
APPLIED ENERGY, 2006, 83 (09) :921-928
[9]
DURGUN I, 1993, 9 NAT S THERM SCI, P439
[10]
CHEOPS: a simplified tool for thermal assessment of Mediterranean residential buildings in hot and cold seasons [J].
Ghrab-Morcos, N .
ENERGY AND BUILDINGS, 2005, 37 (06) :651-662