Applications of electrochemical immunosensors for early clinical diagnostics

被引:152
作者
Bahadir, Elif Burcu [1 ]
Sezginturk, Mustafa Kemal [1 ]
机构
[1] Namik Kemal Univ, Sci & Technol Res Ctr, Tekirdag, Turkey
关键词
Biosensor; Cancer biomarkers; Immunosensor; Electrochemical biosensors; Early diagnosis; PROSTATE-SPECIFIC ANTIGEN; LABEL-FREE IMMUNOSENSOR; SELF-ASSEMBLED MONOLAYERS; SCREEN-PRINTED ELECTRODE; CARDIAC TROPONIN-T; SENSITIVE AMPEROMETRIC IMMUNOSENSOR; SIGNAL AMPLIFICATION STRATEGY; GLASSY-CARBON ELECTRODE; MODIFIED GOLD ELECTRODE; MESOPOROUS SILICA NANOPARTICLES;
D O I
10.1016/j.talanta.2014.08.063
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
Cancer and cardiovascular diseases are the major threats to global health. Hence, there is a growing demand for a range of portable, rapid and low cost biosensing devices for the detection of these diseases. Electrochemical immunosensors are simple, rapid, reliable and inexpensive devices and they have sensitive detection limits to monitor both levels of the biomarkers in normal and patient serum. Due to the specific binding of antibody to its corresponding antigen, immunosensors based on antibody antigen interaction are one of the most widely used analytical techniques in the quantitative detection of these diseases. The changed levels of markers in patients are associated with diseases. In this article the biosensors and biomarkers, which were commonly used in terms of monitoring the diagnosis and treatment of cancer and cardiac diseases, are reviewed. In addition, the developed biosensors are compared in terms of precision, reproducibility, regeneration, stability and specificity. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:162 / 174
页数:13
相关论文
共 149 条
[1]
[Anonymous], Global status report on blood safety and availability 2016
[2]
A novel impedimetric disposable immunosensor for rapid detection of a potential cancer biomarker [J].
Asav, Engin ;
Sezginturk, Mustafa Kemal .
INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2014, 66 :273-280
[3]
Avila B. E., 2013, SENSOR ACTUAT B-CHEM, V188, P212
[4]
Gold nanoparticles mediated label-free capacitance detection of cardiac troponin I [J].
Bhalla, Vijayender ;
Carrara, Sandro ;
Sharma, Priyanka ;
Nangia, Yogesh ;
Suri, C. Raman .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01) :761-768
[5]
Mixed self-assembled monolayer (mSAM) based impedimetric immunosensors for cardiac troponin I (cTnI) and soluble lectin-like oxidized low-density lipoprotein receptor-1 (sLOX-1) [J].
Billah, Md Morsaline ;
Hays, Henry C. W. ;
Hodges, Christopher S. ;
Ponnambalam, Sreenivasan ;
Vohra, Ravi ;
Millner, Paul A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 :361-366
[6]
Directed immobilization of reduced antibody fragments onto a novel SAM on gold for myoglobin impedance immunosensing [J].
Billah, Md Morsaline ;
Hodges, Christopher S. ;
Hays, Henry C. W. ;
Millner, P. A. .
BIOELECTROCHEMISTRY, 2010, 80 (01) :49-54
[7]
Biosensors: the new wave in cancer diagnosis [J].
Bohunicky, Brian ;
Mousa, Shaker A. .
NANOTECHNOLOGY SCIENCE AND APPLICATIONS, 2011, 4 :1-10
[8]
Electrochemical immunoassay for carcinoembryonic antigen based on signal amplification strategy of nanotubular mesoporous PdCu alloy [J].
Cai, Yanyan ;
Li, He ;
Li, Yuyang ;
Zhao, Yanfang ;
Ma, Hongmin ;
Zhu, Baocun ;
Xu, Caixia ;
Wei, Qin ;
Wu, Dan ;
Du, Bin .
BIOSENSORS & BIOELECTRONICS, 2012, 36 (01) :6-11
[9]
Electrochemical biosensor based on self-assembled monolayers modified with gold nanoparticles for detection of HER-3 [J].
Canbaz, Mehmet Cetin ;
Simsek, Cigdem Sayikli ;
Sezginturk, Mustafa Kemal .
ANALYTICA CHIMICA ACTA, 2014, 814 :31-38
[10]
Fabrication of a highly sensitive disposable immunosensor based on indium tin oxide substrates for cancer biomarker detection [J].
Canbaz, Mehmet Cetin ;
Sezginturk, Mustafa Kemal .
ANALYTICAL BIOCHEMISTRY, 2014, 446 :9-18