Mixed self-assembled monolayer (mSAM) based impedimetric immunosensors for cardiac troponin I (cTnI) and soluble lectin-like oxidized low-density lipoprotein receptor-1 (sLOX-1)

被引:25
作者
Billah, Md Morsaline [1 ]
Hays, Henry C. W. [1 ]
Hodges, Christopher S. [2 ]
Ponnambalam, Sreenivasan [3 ]
Vohra, Ravi [3 ]
Millner, Paul A. [1 ]
机构
[1] Univ Leeds, Inst Membrane & Syst Biol, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Leeds, Fac Engn, Inst Particle Sci & Engn, Leeds LS2 9JT, W Yorkshire, England
[3] Univ Leeds, Inst Mol & Cellular Biol, Leeds LS2 9JT, W Yorkshire, England
关键词
Immunosensor; cTnI; sLOX-1; Cardiac pathology; Impedance; LABEL-FREE; FT-IRRAS; BIOTIN; AVIDIN;
D O I
10.1016/j.snb.2012.07.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Immunosensors depend on the specificity of the molecular recognition towards analytes of interest provided by the antibodies. In this study, electrochemical impedance spectroscopy (EIS) was used to monitor the sensor surface assembly and recognition of two different analytes of cardiac pathology, cardiac troponin I (cTnI) and soluble lectin-like oxidized LDL receptor-1 (sLOX-1) on surfaces based on mixed self-assembled monolayers onto gold electrodes. The specificity and longer persistence of cTnI serves as a definitive biomarker in the diagnosis of acute myocardial infarction (AMI). Circulating levels of sLOX-1 serve as a marker for plaque instability or rupture before an AMI becomes apparent and facilitates early diagnosis of acute coronary syndrome (ACS). The immunosensors were highly specific, since a clinically relevant range of analyte concentrations was successfully detected in phosphate buffered saline and in serum with virtually no alteration to the slope of the calibration curve. Detection limits for cTnI and sLOX-1 immunosensors were at least 10(-13) M for each analyte. Atomic force microscopy studies were carried out to study each step of fabrication to elucidate the binding characteristics and surface nanotopography of the mSAM based immunosensors. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:361 / 366
页数:6
相关论文
共 23 条
[1]   Myocardial infarction redefined -: A consensus Document of the Joint European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction [J].
Alpert, JS ;
Antman, E ;
Apple, F ;
Armstrong, PW ;
Bassand, JP ;
de Luna, AB ;
Beller, G ;
Breithardt, G ;
Chaitman, BR ;
Clemmensen, P ;
Falk, E ;
Fishbein, MC ;
Galvani, M ;
Garson, A ;
Grines, C ;
Hamm, C ;
Jaffe, A ;
Katus, H ;
Kjekshus, J ;
Klein, W ;
Klootwijk, P ;
Lenfant, C ;
Levy, D ;
Levy, RI ;
Luepker, R ;
Marcus, F ;
Näslund, U ;
Ohman, M ;
Pahlm, O ;
Poole-Wilson, P ;
Popp, R ;
Alto, P ;
Pyörälä, K ;
Ravkilde, J ;
Rehnquist, N ;
Roberts, W ;
Roberts, R ;
Roelandt, J ;
Rydén, L ;
Sans, S ;
Simoons, ML ;
Thygesen, K ;
Tunstall-Pedoe, H ;
Underwood, R ;
Uretsky, BF ;
Van de Werf, F ;
Voipio-Pulkki, LM ;
Wagner, G ;
Wallentin, L ;
Wijns, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) :959-969
[2]   Raised cardiac troponins - Causes extend beyond acute coronary syndromes [J].
Ammann, P ;
Pfisterer, M ;
Fehr, T ;
Rickli, H .
BMJ-BRITISH MEDICAL JOURNAL, 2004, 328 (7447) :1028-1029
[3]   Release kinetics of serum cardiac troponin I in ischemic myocardial injury [J].
Bertinchant, JP ;
Larue, C ;
Pernel, I ;
Ledermann, B ;
FabbroPeray, P ;
Beck, L ;
Calzolari, C ;
Trinquier, S ;
Nigond, J ;
Pau, B .
CLINICAL BIOCHEMISTRY, 1996, 29 (06) :587-594
[4]   Development of a myoglobin impedimetric immunosensor based on mixed self-assembled monolayer onto gold [J].
Billah, Morsaline ;
Hays, Henry C. W. ;
Millner, Paul A. .
MICROCHIMICA ACTA, 2008, 160 (04) :447-454
[5]   ACC/AHA guidelines for the management of patients with unstable angina and non-ST-segment elevation myocardial infarction: Executive summary and recommendations - A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on the Management of Patients with Unstable Angina) [J].
Braunwald, E ;
Antman, EM ;
Beasley, JW ;
Califf, RM ;
Cheitlin, MD ;
Hochman, JS ;
Jones, RH ;
Kereiakes, D ;
Kupersmith, J ;
Levin, TN ;
Pepine, CJ ;
Schaeffer, JW ;
Smith, EE ;
Steward, DE ;
Theroux, P ;
Gibbons, RJ ;
Alpert, JS ;
Eagle, KA ;
Faxon, DP ;
Fuster, V ;
Gardner, TJ ;
Gregoratos, G ;
Russell, RO ;
Smith, SC .
CIRCULATION, 2000, 102 (10) :1193-1209
[6]   Self-assembled monolayers as a tunable platform for biosensor applications [J].
Chaki, NK ;
Vijayamohanan, K .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (1-2) :1-12
[7]   Label-free impedance biosensors: Opportunities and challenges [J].
Daniels, Jonathan S. ;
Pourmand, Nader .
ELECTROANALYSIS, 2007, 19 (12) :1239-1257
[8]   Disposable amperometric immunosensor system for rabbit IgG using a conducting polymer modified screen-printed electrode [J].
Darain, F ;
Park, SU ;
Shim, YB .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :773-780
[9]   Electrochemical evaluation of avidin-biotin interaction on self-assembled gold electrodes [J].
Ding, SJ ;
Chang, BW ;
Wu, CC ;
Lai, MF ;
Chang, HC .
ELECTROCHIMICA ACTA, 2005, 50 (18) :3660-3666
[10]   Labeless immunosensor assay for fluoroquinolone antibiotics based upon an AC impedance protocol [J].
Garifallou, G.-Z. ;
Tsekenis, G. ;
Davis, F. ;
Higson, S. P. J. ;
Millner, P. A. ;
Pinacho, D. G. ;
Sanchez-Baeza, F. ;
Marco, M.-P. ;
Gibson, T. D. .
ANALYTICAL LETTERS, 2007, 40 (07) :1412-1422