Carotid artery stenosis, occlusion, and pseudo-occlusion: First-pass, gadolinium-enhanced, three-dimensional MR angiography - Preliminary study

被引:117
作者
Remonda, L [1 ]
Heid, O [1 ]
Schroth, G [1 ]
机构
[1] Univ Bern, Inselspital, Dept Neuroradiol, CH-3010 Bern, Switzerland
关键词
carotid arteries; stenosis or obstruction; gadolinium; magnetic resonance (MR); contrast enhancement; vascular studies;
D O I
10.1148/radiology.209.1.9769818
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the accuracy of gadolinium-enhanced three-dimensional magnetic resonance (MR) angiography in the evaluation of carotid artery stenosis. MATERIALS AND METHODS: A prospective blinded comparison of first-pass MR angiography with conventional digital subtraction angiography (DSA) was performed in 21 patients suspected of having carotid artery stenosis. MR angiography was performed on a 1.5-T magnet with gradient overdrive equipment, with a coronal radio-frequency-spoiled, three-dimensional, fast low-angle shot sequence after intravenous injection of contrast material. The guidelines of the North America Symptomatic Carotid Endarterectomy Trial for measuring stenosis of the internal carotid artery were applied on maximum intensity projection images and conventional angiograms. RESULTS: Grading of stenoses at MR angiography agreed with that at DSA in 92% of the 44 carotid arteries. In the 18 carotid arteries with severe stenosis (70%-99%), agreement was 94%. All internal carotid occlusions (n=7) or pseudo-occlusions (n=3) were accurately detected with MR angiography. CONCLUSION: The accuracy of gadolinium-enhanced MR angiography in characterizing the degree of carotid stenosis was high. Findings with MR angiography were accurate for differentiating between occlusion and pseudo-occlusion.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 35 条
[21]  
MATTLE HP, 1991, J VASC SURG, V13, P838
[22]   ROLE OF DUPLEX US AS A SCREENING-TEST FOR CAROTID ATHEROSCLEROTIC DISEASE - BENEFIT WITHOUT COST [J].
POLAK, JF .
RADIOLOGY, 1995, 197 (03) :581-582
[23]   NONINVASIVE CAROTID EVALUATION - CARPE-DIEM [J].
POLAK, JF .
RADIOLOGY, 1993, 186 (02) :329-331
[24]   DETECTION OF INTERNAL CAROTID-ARTERY STENOSIS - COMPARISON OF MR ANGIOGRAPHY, COLOR DOPPLER SONOGRAPHY, AND ARTERIOGRAPHY [J].
POLAK, JF ;
BAJAKIAN, RL ;
OLEARY, DH ;
ANDERSON, MR ;
DONALDSON, MC ;
JOLESZ, FA .
RADIOLOGY, 1992, 182 (01) :35-40
[25]   CAROTID ENDARTERECTOMY - PREOPERATIVE EVALUATION OF CANDIDATES WITH COMBINED DOPPLER SONOGRAPHY AND MR ANGIOGRAPHY - WORK IN PROGRESS [J].
POLAK, JF ;
KALINA, P ;
DONALDSON, MC ;
OLEARY, DH ;
WHITTEMORE, AD ;
MANNICK, JA .
RADIOLOGY, 1993, 186 (02) :333-338
[26]   BREATH-HOLD GADOLINIUM-ENHANCED MR-ANGIOGRAPHY OF THE ABDOMINAL-AORTA AND ITS MAJOR BRANCHES [J].
PRINCE, MR ;
NARASIMHAM, DL ;
STANLEY, JC ;
CHENEVERT, TL ;
WILLIAMS, DM ;
MARX, V ;
CHO, KJ .
RADIOLOGY, 1995, 197 (03) :785-792
[27]   GADOLINIUM-ENHANCED MR AORTOGRAPHY [J].
PRINCE, MR .
RADIOLOGY, 1994, 191 (01) :155-164
[28]   PROGNOSTIC VALUE AND REPRODUCIBILITY OF MEASUREMENTS OF CAROTID STENOSIS - A COMPARISON OF 3 METHODS ON 1001 ANGIOGRAMS [J].
ROTHWELL, PM ;
GIBSON, RJ ;
SLATTERY, J ;
WARLOW, CP .
STROKE, 1994, 25 (12) :2440-2444
[29]   CONTRAST-ENHANCED MR ANGIOGRAPHY [J].
RUNGE, VM ;
KIRSCH, JE ;
LEE, C .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01) :233-239
[30]  
TAYLOR DW, 1991, NEW ENGL J MED, V325, P445