Determination of meropenem in serum by high-performance liquid chromatography with column switching

被引:30
作者
Bompadre, S
Ferrante, L
De Martinis, M
Leone, L [1 ]
机构
[1] Univ Ancona, Fac Med, Inst Biomed Sci, I-60131 Ancona, Italy
[2] Univ Aquila, Dept Internal Med, I-67100 Laquila, Italy
关键词
column switching; sample preparation; meropenem; antibiotics;
D O I
10.1016/S0021-9673(98)00249-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, accurate and sensitive liquid chromatographic assay with on-line solid-phase extraction for determination of meropenem in serum is described. Sample was directly injected onto the extraction column for sample clean-up and extraction. Thereafter, using an on-line column-switching system the drug was quantitatively transferred and separated on a C-18 analytical column. Ultraviolet absorption at 298 nm was used for detection. The assay was linear from 1 to 100 mu g/ml. Recovery was 98.5%. Based on a 20-mu l sample volume (serum-water, 1:1, v/v), detection limit was 0.1 mu g/ml. An application of the method to study the pharmacokinetics of meropenem is given. (C) 1998 Elsevier Science BN. All rights reserved.
引用
收藏
页码:249 / 253
页数:5
相关论文
共 12 条
[1]   DETERMINATION OF MEROPENEM IN PLASMA BY HIGHPERFORMANCE LIQUID-CHROMATOGRAPHY AND A MICROBIOLOGICAL METHOD [J].
ALMESHAL, MA ;
RAMADAN, MA ;
LOTFI, KM ;
SHIBL, AM .
JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 1995, 20 (03) :159-163
[2]   THE PHARMACOKINETICS OF MEROPENEM IN VOLUNTEERS [J].
BAX, RP ;
BASTAIN, W ;
FEATHERSTONE, A ;
WILKINSON, DM ;
HUTCHISON, M ;
HAWORTH, SJ .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1989, 24 :311-320
[3]   Column-switching high-performance liquid chromatographic assay for minocycline of nude mice serum [J].
Bompadre, S ;
Ferrante, L ;
Leone, L ;
Montesi, M ;
Possati, L .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (08) :1257-1267
[4]   ONLINE SOLID-PHASE EXTRACTION OF CEFTAZIDIME IN SERUM AND DETERMINATION BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BOMPADRE, S ;
FERRANTE, L ;
ALO, FP ;
LEONE, L .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 669 (02) :265-269
[5]  
BURMAN LA, 1991, J ANTIMICROB CHEMOTH, V27, P219
[6]   COLUMN-SWITCHING TECHNIQUES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF DRUGS IN BIOLOGICAL SAMPLES [J].
CAMPINSFALCO, P ;
HERRAEZHERNANDEZ, R ;
SEVILLANOCABEZA, A .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 619 (02) :177-190
[7]   High-performance liquid chromatographic assay for meropenem in serum [J].
Elkhaili, H ;
Niedergang, S ;
Pompei, D ;
Linger, L ;
Leveque, D ;
Jehl, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1996, 686 (01) :19-26
[8]   A COMPARISON OF THE PHARMACOKINETICS OF MEROPENEM AFTER ADMINISTRATION BY INTRAVENOUS-INJECTION OVER 5 MINUTES AND INTRAVENOUS-INFUSION OVER 30 MINUTES [J].
KELLY, HC ;
HUTCHISON, M ;
HAWORTH, SJ .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1995, 36 :35-41
[9]   PHARMACOKINETICS OF MEROPENEM (ICI-194,660) AND ITS METABOLITE (ICI-213,689) IN HEALTHY-SUBJECTS AND IN PATIENTS WITH RENAL IMPAIRMENT [J].
LEROY, A ;
FILLASTRE, JP ;
BORSALEBAS, F ;
ETIENNE, I ;
HUMBERT, G .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1992, 36 (12) :2794-2798
[10]   PHARMACOKINETICS OF MEROPENEM COMPARED TO IMIPENEM-CILASTATIN IN YOUNG, HEALTHY-MALES [J].
NILSSONEHLE, I ;
HUTCHISON, M ;
HAWORTH, SJ ;
NORRBY, SR .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1991, 10 (02) :85-88