Ultrasonically activated shears in thyroid surgery

被引:61
作者
Voutilainen, PE [1 ]
Haapiainen, RK [1 ]
Haglund, CH [1 ]
机构
[1] Univ Helsinki, Cent Hosp, Dept Surg 2, FIN-00290 Helsinki, Finland
关键词
D O I
10.1016/S0002-9610(98)00073-7
中图分类号
R61 [外科手术学];
学科分类号
摘要
BACKGROUND: Ultrasonically activated shears (UAS) have been documented to be both safe and fast devices in laparoscopic surgery. We studied whether the use of UAS would have some advantage in thyroid surgery. METHODS: Thyroidectomies, performed by one senior endocrine surgeon between December 1996 and February 1997, were retrospectively matched, with patients operated on by the same surgeon using the conventional method. RESULTS: Six pairs of total thyroidectomies and one pair of lobectomies could be matched. Mean operating time was 100 minutes for the patients operated on with the UAS and 154 minutes for the patients operated on with the conventional method. The mean operating time with the UAS was thus on average 64.6% of the operation time with the conventional method, with a 95% confidence interval from 50.1% to 83.5% (t = 4.00, 6 df, P = 0.007). CONCLUSIONS: In this material the use of UAS reduced significantly operating time in thyroidectomies. (C) 1998 by Excerpta Medica, Inc.
引用
收藏
页码:491 / 493
页数:3
相关论文
共 10 条
[1]   STATISTICS AND ETHICS IN MEDICAL-RESEARCH - STUDY DESIGN [J].
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1980, 281 (6250) :1267-1269
[2]  
AMARAL JF, 1995, SURG LAPAROSC ENDOSC, V5, P255
[3]  
ARMITAGE P, 1994, STAT METHODS MED RES, P195
[4]   Improving the quality of reporting of randomized controlled trials - The CONSORT statement [J].
Begg, C ;
Cho, M ;
Eastwood, S ;
Horton, R ;
Moher, D ;
Olkin, I ;
Pitkin, R ;
Rennie, D ;
Schulz, KF ;
Simel, D ;
Stroup, DF .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (08) :637-639
[5]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[6]   LOCAL COMPLICATIONS AFTER SURGICAL RESECTION FOR THYROID-CARCINOMA [J].
FLYNN, MB ;
LYONS, KJ ;
TARTER, JW ;
RAGSDALE, TL .
AMERICAN JOURNAL OF SURGERY, 1994, 168 (05) :404-407
[7]   Laparosonic coagulating shears: Alternative method of hemostatic control of unsupported tissue [J].
Hoenig, DM ;
Chrostek, CA ;
Amaral, JF .
JOURNAL OF ENDOUROLOGY, 1996, 10 (05) :431-433
[8]   Early impressions of the harmonic scalpel [J].
Paredes, J ;
Borges, M ;
Coulson, A .
ANESTHESIOLOGY, 1996, 85 (04) :947-947
[9]  
SWANSTROM LL, 1995, J AM COLL SURGEONS, V181, P347
[10]  
*ULTR INC, HARM SCALP OP MAN