A-mode ultrasound-based registration in computer-aided surgery of the skull

被引:27
作者
Amstutz, C
Caversaccio, M [1 ]
Kowal, J
Bächler, R
Nolte, LP
Häusler, R
Styner, M
机构
[1] Univ Hosp Bern, Dept Otolaryngol Head & Neck Surg, CH-3010 Bern, Switzerland
[2] Univ Bern, Maurice E Res Ctr Orthopaed Surg, CH-3012 Bern, Switzerland
关键词
D O I
10.1001/archotol.129.12.1310
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 [耳鼻咽喉科学];
摘要
Objective: To evaluate the integration and accuracy of A (amplitude)-mode ultrasound-based surface matching for noninvasive registration of the head into a frameless computer-aided surgery system for otorhinology and skull base surgery. Design: Experimental study and case series. Setting: Academic medical center. Patients: Twelve patients underwent anterior and paranasal skull base surgery with the routine use of a computer-aided surgery system. Interventions: A computer-aided surgery system, based on an optoelectronic localizer, was used to track the skull and the surgical tools, including the A-mode ultrasound probe. The A-mode probe was a 10-MHz immersion transducer. An acoustic lens attached to the transducer focused the ultrasonic beam to a depth of 1 to 10 nun. Accuracy tests were performed for the ultrasound setup. Different surface point distributions were evaluated with respect to matching accuracy on a human cadaver skull specimen equipped with fiducial markers. The matching comparison was based on the fichicial registration error. For the clinical evaluation, the laboratory setup was transferred to the operating room. Main Outcome Measures: Noninvasive registration of the skull by using A-mode ultrasound in computer-aided surgery (practical and clinical measurements). Results: The accuracy tests on the human skull specimen revealed that the mean SD fiducial registration error was 1.00 +/- 0.19 min in the best series for A-mode ultrasound surface matchings and was robust with respect to different sets of surface points. The mean SD root mean square error from the 12 A-mode ultrasound matchings in the patient study was 0.49 +/- 0.20 mm. Conclusion: A-mode ultrasound surface matching can be used as a noninvasive and accurate registration procedure in computer-aided surgery of the head.
引用
收藏
页码:1310 / 1316
页数:7
相关论文
共 20 条
[1]
Ault T, 1995, J Image Guid Surg, V1, P94, DOI 10.1002/(SICI)1522-712X(1995)1:2<94::AID-IGS4>3.0.CO
[2]
2-G
[3]
BARBE C, 1993, P ANN INT C IEEE ENG, P160
[4]
Caversaccio M, 2000, AM J OTOL, V21, P863
[5]
Caversaccio M, 1999, Comput Aided Surg, V4, P328, DOI 10.1002/(SICI)1097-0150(1999)4:6<328::AID-IGS5>3.3.CO
[6]
2-P
[7]
Christensen D., 1988, ULTRASONIC BIOINSTRU
[8]
3-D ultrasound imaging: A review [J].
Fenster, A ;
Downey, DB .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06) :41-51
[9]
Experience with various 3-dimensional navigation systems in head and neck surgery [J].
Gunkel, AR ;
Freysinger, W ;
Thumfart, WF .
ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2000, 126 (03) :390-395
[10]
Development of a frameless and armless stereotactic neuronavigation system with ultrasonographic registration [J].
Hata, N ;
Dohi, T ;
Iseki, H ;
Takakura, K .
NEUROSURGERY, 1997, 41 (03) :608-613