Gold-Composite Electrodes for Hydrocarbon Sensors Based on YSZ Solid Electrolyte

被引:26
作者
Westphal, D. [1 ]
Jakobs, S. [2 ]
Guth, U. [3 ]
机构
[1] Sensor Res Ctr Greifswald, Greifswald, Germany
[2] Ernst Moritz Arndt Univ Greifswald, Inst Chem & Biochem, D-17487 Greifswald, Germany
[3] Tech Univ Dresden, Kurt Schwabe Inst Meinsberg, Dresden, Germany
关键词
Chromite; Ga2O3; Cell Voltage; Yttria Stabilise Zirconia; Pure Gold;
D O I
10.1007/BF02419226
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In potentiometric zirconia based sensors gold electrodes show a high sensitivity for hydrocarbons (HC's) when the measurements are carried out in non equilibrated oxygen containing gas mixtures at temperatures < 700 degrees C. This behaviour explained by mixed potential theory is not stable and depends strongly on preparation and particularly on measuring conditions. To modify the electrode behaviour composites consisting of gold and gallium oxide were investigated. Gold pastes with different amount of Ga(2)O(3) were prepared and screen printed on YSZ pellets. After sintering at defined temperatures between 900 and 950 degrees C the cells were tested regarding the electrode behaviour in a C(3)H(6), O(2) gas mixture using a platinum air reference electrode. These composite electrodes show as compared with pure gold an enhanced sensitivity at low propylene concentrations and a time-independent characteristic at high concentrations of C(3)H(6). The optimal composition is found to be at 20 mass-% Ga(2)O(3). This electrode can be treated in reducing gases at temperatures 850 degrees C without changing its characteristics.
引用
收藏
页码:182 / 186
页数:5
相关论文
共 8 条
[1]   Solid-stale mixed potential gas sensors: theory. experiments and challenges [J].
Garzon, FH ;
Mukundan, R ;
Brosha, EL .
SOLID STATE IONICS, 2000, 136 (136-137) :633-638
[2]   Possibilities of NOx and CHx Determination using Galvanic Cells with Perovskite-Electrodes on YSZ [J].
Jakobs, S. ;
Hartung, R. ;
Lawrenz, U. ;
Sandow, P. ;
Schoenauer, U. ;
Guth, U. .
IONICS, 1996, 2 (5-6) :451-458
[3]   Metal oxide sensors [J].
Meixner, H ;
Lampe, U .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 33 (1-3) :198-202
[4]   Chemical Modifications of Chromite - Electrodes on YSZ and their Influence on the Non-Nernstian Potential Behaviour [J].
Sandow, K. -P. ;
Jakobs, S. ;
Westphal, D. ;
Thiemann, S. ;
Hartung, R. ;
Schoenauer, U. ;
Guth, U. .
IONICS, 1996, 2 (5-6) :435-441
[5]  
SOMOV S, 1996, SENSOR ACTUAT B-CHEM, V35, P409
[6]   Chemical Modifications of Au-Electrodes on YSZ and their Influence on the Non-Nernstian Behaviour [J].
Thiemann, S. ;
Hartung, R. ;
Guth, U. ;
Schoenauer, U. .
IONICS, 1996, 2 (5-6) :463-467
[7]  
THIEMANN S, 1996, SOLID STATE IONICS, V86, P86
[8]  
Vetter K.J., 1961, ELEKTROCHEMISCHE KIN