Influence of the solvent on the gas chromatographic behaviour of urea herbicides

被引:23
作者
Berrada, H [1 ]
Font, G [1 ]
Moltó, JC [1 ]
机构
[1] Univ Valencia, Fac Farm, Lab Bromatol & Toxicol, E-46100 Burjassot, Spain
关键词
gas chromatography - mass spectrometry; urea herbicides; thermal degradation; phenylisocyanates;
D O I
10.1007/BF02492254
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Degradation products of chlorsulfuron, chlortoluron, diuron, fluometuron, isoproturon, linuron, metabenzthiazuron, metobromuron, and monuron formed in the gas chromatographic injector have been used for identification of the respective herbicides. Mass spectra of the derived compounds were obtained with a quadrupole mass spectrometric detector working in scan mode (20-450 amu). The compounds generated often depended on the solvent used for phenylurea herbicide injection (ethanol, methanol, dichloromethane, and acetonitrile). When methanol and ethanol were used as solvents the major products formed from phenylureas were carbamic acid esters. When acetonitrile or dichloromethane were used the main derivatives were phenylisocyanates. Chlorsulfuron and metabenzthiazuron, however, generated a triazine plus a phenylsulfonamide and a benzothiazolamine, respectively, irrespective of the solvent used. Linuron and diuron behaved similarly and gave degradation products with the same mass spectra. The thermal reactions occurred instantaneously in the injector block and were promoted by the high temperature selected (300 degreesC). Determination of the compounds derived from urea herbicides, by use of a 30 m BP10 column and a selected ion registering (SIR) program based on two or three ions, can be used for sensitive detection of the presence of urea herbicides in environmental extracts. With standards in methanol instrument detection limits ranged from 0.1 pg for chlorsulfuron (detected as 2-chlorobenzensulfonamide) to 1 pg for monuron and metobromuron (both detected as their carbamic acid methyl esters). RSD were below 9% at the 5 ng L-1 level. The response was linearly dependent on quantity (r > 0.9986) in the 5 ng L-1 to 25 mug L-1 range. Unequivocal identification of some phenylurea herbicides was not always possible because some herbicides with similar structures, for example diuron and linuron, gave the same derivative.
引用
收藏
页码:253 / 262
页数:10
相关论文
共 36 条
[1]   Comparison of automated on-line solid-phase extraction followed by liquid chromatography mass spectrometry with atmospheric pressure chemical ionization and particle beam mass spectrometry for the determination of a priority group of pesticides in environmental waters [J].
Aguilar, C ;
Ferrer, I ;
Borrull, F ;
Marcé, RM ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) :147-163
[2]   MULTI-RESIDUE PESTICIDE ANALYSIS IN ENVIRONMENTAL WATER SAMPLES USING SOLID-PHASE EXTRACTION DISCS AND GAS-CHROMATOGRAPHY WITH FLAME THERMIONIC AND MASS-SELECTIVE DETECTION [J].
ALBANIS, TA ;
HELA, DG .
JOURNAL OF CHROMATOGRAPHY A, 1995, 707 (02) :283-292
[3]   SOLID-PHASE EXTRACTION OF PESTICIDES FROM SURFACE-WATER USING BULK SORBENTS [J].
BENGTSSON, S ;
RAMBERG, A .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1995, 33 (10) :554-556
[4]   Possibilities of gas chromatography atomic emission detection in pesticide multiresidue analysis - Application to herbicide analysis in soils [J].
Bernal, JL ;
delNozal, MJ ;
Martin, MT ;
Jimenez, JJ .
JOURNAL OF CHROMATOGRAPHY A, 1996, 754 (1-2) :245-256
[5]  
Bossi R, 1998, J AOAC INT, V81, P775
[6]   APPLICATION OF ONLINE SOLID-PHASE EXTRACTION FOLLOWED BY LIQUID CHROMATOGRAPHY-THERMOSPRAY MASS-SPECTROMETRY TO THE DETERMINATION OF PESTICIDES IN ENVIRONMENTAL WATERS [J].
CHIRON, S ;
DUPAS, S ;
SCRIBE, P ;
BARCELO, D .
JOURNAL OF CHROMATOGRAPHY A, 1994, 665 (02) :295-305
[7]   Development of a multiresidue method for analyzing pesticide traces in water based on solid-phase extraction and electrospray liquid chromatography mass spectrometry [J].
Crescenzi, C ;
DiCorcia, A ;
Guerriero, E ;
Samperi, R .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (02) :479-488
[8]   Multiresidue method for determination of post emergence herbicides in water by HPLC/ESI/MS in positive ionization mode [J].
D'Ascenzo, G ;
Gentili, A ;
Marchese, S ;
Marino, A ;
Perret, D .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (09) :1340-1347
[9]  
DAMATO A, 1993, J AOAC INT, V76, P657
[10]   Multiresidue analysis of pesticides in fruits and vegetables by gel permeation chromatography followed by gas chromatography with electron-capture and mass spectrometric detection [J].
Gelsomino, A ;
Petrovicova, B ;
Tiburtini, S ;
Magnani, E ;
Felici, M .
JOURNAL OF CHROMATOGRAPHY A, 1997, 782 (01) :105-122